storage heater (maximum 150mm far from the hot water outlet from the heater) and the
sensor should be well insulated.
2) Tankless heater.
This type of auxiliary heater shall be installed in the line which is parallel with the heat pump
system as illustrated in picture 5.4a or 5.4b. A flow switch is requested to be installed at the
outlet piping.
3) Static heating element.
This type of auxiliary heater could be installed inside of the tank as illustrated in picture 5.4c
(for vertical tank) and 5.4d (for horizontal tank). Please determine the installation height
based on the actual needs.
Please read information in chapter 5.9 for the tank design requirements.