Page 2
TO ASSEMBLE: TO INSTALL DIE SET: THE #5-H LOCOLOC HYDRAULIC Remove four screws on right side of the upper ® PRESS AND PUMP HAS BEEN and lower dies, then slide the dies out. SHIPPED IN TWO CRATES. To install, place new dies in die shoe, lining up screw holes with die shoe.
TO CHECK HYDRAULIC OIL LEVEL: To check hydraulic oil level, remove cap. Oil level should be approx. 2 inches below the frame. FIGURE 4 5. Loosen the 3/8” X 16” allen head bolt, this secures the ram return micro switch bracket.
NOTE: Dies need not to be fully closed to TO SET PRESSURE: achieve correct swage dimension. In fact, some dies are designed to maintain gap while under pressure. 5/16”, 3/8”, 7/16", and Always make sure the die set is in the die 1/2"...