Download Print this page

Loos & Co Locoloc 3-H Operating Instructions Manual

Hydraulic handswager

Advertisement

Quick Links

#3-H
®
L
OCOLOC
H
H
YDRAULIC
ANDSWAGER
#3-K (kit shown)
O
I
M
PERATING
NSTRUCTION
ANUAL

Advertisement

loading

Summary of Contents for Loos & Co Locoloc 3-H

  • Page 1 #3-H ® OCOLOC YDRAULIC ANDSWAGER #3-K (kit shown) PERATING NSTRUCTION ANUAL...
  • Page 2 WARNING Read instruction manual before use. Wear safety goggles and protective gear. Do not use on electrical circuits. Keep all body parts clear of swaging dies. CONTENTS Size - - - - - - - - - - - - - - - - - - - - - - Part List - - - - - - - - - - - - - - - - - - - Operation Instruction...
  • Page 3 Hydraulic compression tool with a two stage section for use with interchangeable die sets, 1/4 to 1/2 inch.  Complete with plastic carrying case.  Dies sold separately with gauges included.  Head rotates 180° for difficult situations. 23” 6” Weight : 13 lbs.
  • Page 5 #3-H Break Down List Part list is only for reference, parts are not available for individual sale.
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS (6). Push TO INSERT A DIE IN THE TOP OF THE HEAD the die release button (4) and place one die of the set in the top of the head, center it and release the button. INSERT THE OTHER DIE IN THE BOTTOM OF THE Depress the die release pin (15) and place the other HEAD die of the set in the bottom of the head and release the pin.
  • Page 7 OPERATING INSTRUCTIONS 4. OPERATE THE PUMP HANDLE (37) until the dies are closed. If the dies are not clearly visible, the pumping should continue until a sound from bypass valve (48) is heard. First Stage, the pumping sound will accompany a reduction in the force required to close the pump handle.
  • Page 8 OPERATING INSTRUCTIONS (Continuation) RELEASE PRESSURE AFTER OPERATION. Release pressure by twisting pump handle (37) clock- wise while holding the handle in the open position, then move the handle down into the closed position. WARNING: Keep finger s clear fr om the dies and ram (14) during operation Properly swaged sleeve.
  • Page 9 REFILL OIL 1. Place the tool, head downward, and hold it in a vertical position. 2. Release pressure by twisting the handle clockwise (37) and press down. 3. Remove the body handle assembly (78 - 80) 4. Pump the handle several times and release pres- sure.
  • Page 10 PREVENTIVE MAINTENANCE 1. Do not pump the tool to closed jaw position when the dies are not placed in the head. This can place excessive pressure on the jaws result- ing in fracture or distortion of the jaws. If the jaws are mistakenly closed without the dies, do not continue to apply pressure by further pumping.
  • Page 11 DIES ALWAYS USE GAUGE TO CHECK THE AFTER SWAGE DIMENSION. Flexible Cable 7x19 / 6x19 Construction. Information below for: OR MAXIMUM SAFETY AND HOLDING POWER WE RECOMMEND USING 3/8” SLEEVES ON AND LARGER...
  • Page 12 901 Industrial Blvd. Naples, FL 34104 Phone: 800-321-LOOS (5667) / 239-643-5667 Fax: 239-643-4558 E-mail : info@loosnaples.com Website: www.loosnaples.com INST-14 Revised 11/19/13...

This manual is also suitable for:

Locoloc 3-k