Installation
Building-in dimensions
Dimensions are given in mm.
Installation in a tall or base unit
When building the oven into a base unit underneath a cooktop, please also
observe the installation instructions for the cooktop as well as the building-in
height required for the cooktop.
The HAL 5900 trim, available as an optional accessory, is only required when
building the oven into a base unit.
11194540-03

Advertisement

Table of Contents
loading

Summary of Contents for Miele HAL 5900

  • Page 1 When building the oven into a base unit underneath a cooktop, please also observe the installation instructions for the cooktop as well as the building-in height required for the cooktop. The HAL 5900 trim, available as an optional accessory, is only required when building the oven into a base unit.
  • Page 2: Installation

    *INSTALLATION* 11194540-03 Installation Tall unit side view...
  • Page 3 *INSTALLATION* 11194540-03 Installation Base unit side view The HAL 5900 trim is available as an optional accessory.  Fix the HAL trim into the unit cut-out under the worktop.
  • Page 4 *INSTALLATION* 11194540-03 Installation Connections and ventilation a Front view b Mains connection cable, length = 2,000 mm c No connections permitted in this area d Ventilation cut-out, min. 150 cm²...
  • Page 5: Installing The Oven

    *INSTALLATION* 11194540-03 Installation Installing the oven For safety reasons, the oven may only be used after it has been fully installed. The oven requires a sufficient supply of cool air for efficient operation. The required supply of cool air must not be excessively heated by other heat sources (e.g.
  • Page 6: Electrical Connection

    Please ensure the liable for unauthorised work. connection data matches the household supply. Ensure power is not supplied to the  When contacting Miele, please quote appliance until after installation or the following: repair work has been carried out. – Model number All electrical work must be –...
  • Page 7 *INSTALLATION* 11194540-03 Installation Three phase Single phase Under adverse conditions of the power supply network this device can cause irritating voltage fluctuations in single phase connection. If the network impedance at the point of coupling to the public supply network is higher than 0.42 Ω, additional measures may be required to avoid these irritations.