PARTS LIST

ITEM NO.
PART NO.
1
56073C
Bubbler Assy
2
28843C
Back Panel Assy EDFPBW(V)114C
3
98871C
Kit- Push Button/Spring/Pin/Washer
4
55996C
Strainer
5
1000001772
Kit - Elbow 1/4 Stem x 1/4 (3 Pcs) 70817C
6
75632C
Setscrew - #10-32 x .31
7
75560C
Screw - 5/16-18 x 1.00 HHMS
8
97446C
VR Bubbler Assy
9
38417001
Screw - #8-18 x .37 HHSM
10
70432C
Screw - #8-32 x .38 THSM
11
28708C
Basin - Swirlflow
12
28473C
Lower Shell
13
45767C
Fountain Body
14
28343C
Cover Plate
15
45781C
Sleeve
16
28397C
Back Panel
17
56092C
Poly Tubing (Cut To Length)
18
98530C
Kit - Regulator/Holder/Nut
19
111008343890
Screw - #10-24 x .62 HHMS
20
AP99
AP-99 Panel (Optional)
21
56163C
Gasket - Drain
22
0000000930
Assy - Drain/Tailpipe
23
45768C
Plug - Drain 1-1/2"
NS
27089C
Hanger Bracket
NS = NOT SHOWN
Figure 16 – Back Panel Assembly
Installing Back Panel: When installing back panel
assy. (Item 2) with MPW (Mounting Plate), attach
channel braces as shown above. Remove the pro-
tective backing from the tape installed on the braces.
Line up the corresponding holes in the braces and
back panel and press firmly in place.
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com
97921C (Rev. F - 02/18)
EDFPB114C, EDFPBWM114C, EDFPBV114C, EDFPBWMV114C
DESCRIPTION
2
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
WWW.RESTROOMDIRECT.COM
TROUBLESHOOTING & MAINTENANCE
Orifice Assembly: Mineral deposits on orifice
can cause water flow to
spurt or not regulate. Mineral
deposits may be removed from
the orifice by poking with a
small round file not over 1/8"
diameter, or using a small
diameter wire.
Stream Regulator: If orifice is clean, regulate flow
as in Step 8 of the installation instructions. If replace-
ment is necessary, see parts list for correct regulator
part number.
Actuation of Quick Connect Water Fittings: Cooler
is provided with lead-free
connectors which utilize an
o-ring water seal. To remove
tubing from the fitting, relieve
water pressure, push in on
the gray collar while pulling
on the tubing. (See Figure
15) To insert tubing, push
tube straight into fitting until
it reaches a positive stop
(approximately 3/4").
Figure 15 – Quick Connect Fittings
4
Figure 17 – Water Supply Connections
Page 8
704 • 937• 2673
DO NOT file or cut
orifice material.
129 Oakpark Dr., Unit A, Mooresville, NC 28115