Download Print this page

Installation Instructions - Elkay EDFPB114C Installation & Use Manual

Fountains with flexi-guard

Advertisement

EDFPB114C EDFPBWM114C EDFPBV114C EDFPBWMV114C
5/16" Studs - Supplied with MP86
14
10
Figure 7 - EDFPB114C Fountain Installation
Figure 8 - AP-99 Panel (Optional)
EDFPB114C W/MP86 MTG. PLT.
1. Wall should already be framed for the fountain using
20
Page 5
WWW.RESTROOMDIRECT.COM

Installation Instructions:

the positioning dimensions shown in Figure 1. Shown
dimensions pertain to installation location (framing
must support up to 300 lbs. weight). These
dimensions are required for compliance with ANSI
Standard A117.0.
2. Install rough-in plumbing as shown in Figure 1. Run
supply water inlet line through the back panel. Install a
service stop (not provided). Turn on supply water and
flush thoroughly.
3. Install fountain. Remove screw (Item 10) from cover
plate and slide cover plate (Item 14) toward basin.
Mount the fountain to the wall and mounting plate with
(4) 5/16" hex nuts (provided with mounting plate).
Tighten securely. (See Figure 7)
4. Determine required length of waste line and cut to
appropriate length. 1-1/4" O.D. waste tube furnished.
1-1/4" slip trap, waste elbow and extension not
provided.
5. Make water supply connections from service stop to
the 3/8" O.D. unplated copper tube coming out of the
strainer. Turn on water supply and check for leaks
(See Figure 17). Newly installed water supply line
should be insulated after leak check is completed.
CAUTION: DO NOT SOLDER tubes inserted
into the strainer as damage to the
o-rings may result.
6. These products are designed to operate on
20-105 PSI supply line pressure. If the inlet
pressure is above 105 PSI, a pressure regulator
must be installed in the supply line. Any damage
caused by reason of connecting these products to
supply line pressures lower than 20 PSI or higher
than 105 PSI is not covered by warranty.
7. Check stream height from bubbler. Stream height is
factory set at 35 PSI. If supply pressure varies
greatly from this, remove push button (Item 3 -
Figure 14) and adjust the screw on the regulator
(Item 18 - Figure 14). To remove push button,
remove setscrew from bottom of sleeve (Item 15).
Insert a small punch in screw hole and push
up while grasping the push button and pull forward
removing the push button. Clockwise adjustment
will raise stream height and counterclockwise
movement will lower stream height. For best
adjustment stream should hit basin approximately
6-1/2" from the bubbler. Reassemble push button
by pushing in on button until the push button
catches in the sleeve. Reinstall the setscrew
(Item 6) in the sleeve (Item 15).
704 • 937• 2673
129 Oakpark Dr., Unit A, Mooresville, NC 28115
97921C (Rev. F - 02/18)

Advertisement

loading

This manual is also suitable for: