Ahnet Protocol - ARTHUR HOLM DynamicCableRetract AHDCRHDMI User Manual

Hdmi motorised cable retraction system
Table of Contents

Advertisement

AHNET PROTOCOL

Communications protocol
COMMUNICATION
CONNECTION
WIRING
Speed and configuration
BAUD RATE
DATA BITS
PARITY
STOP BITS
Wiring Diagram
1. Data TX +
2. Data TX –
3. Data RX +
4. NC
5. NC
6 .Data RX
7. NC
8. NC
Connection
PINS 1 & 2
The units respond
PINS 3 & 6
The units receive instructions
Protocol to control the unit by addressable RS422 bus.
You can connect up to 30 monitors on the same RS422 bus.
You can use a AH Interface Ethernet, to control the RS422 bus.
The units should have a set address and the address must start by 1.
Maximum cable length between ends, 500 m/1640 ft.
22
RS422
RJ45
CAT-5
38400
8
NONE
1
RJ-45

Advertisement

Table of Contents
loading

Table of Contents