HOW TO CHANGE A "DEFROST CYCLE"
May need to unlock control.
This can only be changed if defrost mode parameter (DFM) is set for "RTC".
WHY:
THE DEFROST TIME IS THE TIME OF DAY DEFROST CYCLES ARE INITIATED.
Time of Day must be set ensure that factory set defrost times are
occur at the correct times. By adding a cycle you will be adding an
extra specifi c defrost start time.
HOW:
A. To see the defrost times press and hold the info button
To see the defrost times press and hold the info button
the stand-by button
the stand-by button
See image 1.
B. Push the "up" button
Push the "up" button
C. Press and hold the info button
Press and hold the info button
See image 3.
Note: Clock times are displayed in 24 hour format ranging from 0-23.5.
D. Release and push the info button
Release and push the info button
which show the factory pre-set defrost times. See image 4.
Additional time of day may be added when the time for defrost
shows "---".
E. While pressing and holding the info button
While pressing and holding the info button
down button to change "defrost time". See image 5.
F. Once the "defrost time" has been added release the info
Once the "defrost time" has been added release the info
Wait 30 seconds for the display to show temperature. See image 6.
ALL OTHER SETTINGS ARE FACTORY PRE-SET AND SHOULD NOT BE CHANGED.
If you have any questions, please call TRUE technical service.
Phone: 800-325-6152 • Email: service@truemfg.com
21
LAE Electronic Control
Manual Defrost/
Down Button
at the same time.. "ScL" will appear.
at the same time.. "ScL" will appear.
until "dh1" appears. See image 2.
until "dh1" appears. See image 2.
to see the "defrost time".
to see the "defrost time".
to scroll "dh1" - "dh6"
to scroll "dh1" - "dh6"
press the up or
press the up or
............ www.truemfg.com ............
Manual Activation/
Up Button
and
and
button.
button.
LAE Control Icons
Compressor
Running
Evaporator Fan
Running
Cabinet in Defrost
Activation of 2nd
Parameter Set - NA
Alarm - NA
Stand-By
Button
1
2
3
4
5
6
21