Download Print this page

Mounting Your Extractor - Prima PRAE0030 Manual For Installation, Use And Maintenance

Advertisement

Mounting Your
Extractor
Your extractor can be used to filter and
recycle the air within your kitchen, or to
extract the air outside.
When installing this appliance over a
hob, the clearance between the extractor
and the hob must be equal to or exceed
550mm. This instruction overrides the
instructions supplied with the hob.
(The height should be measured from
the top of the hotplates or burners).
Where the extractor is to be installed
above a non hob, the instructions
supplied with the hob may dictate that
the height required above the hob is
greater than 550mm.
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH A
GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND
EXTRACTOR MUST BE AT LEAST 760mm.
The width of any hob must not be greater than the width of the
extractor installed above it.
12
D
B
A
Gas: 550mm minimum
Electric: 550mm minimum
Fig. 13
PRAE0030
A
103
B
330
C
118
D
75
C