4 . INSTALLATION

WARNING
When installing to the SAFETY RELAY BOX, turn the CONTROLLER and machine power supply OFF.
If the power is on when installing to the SAFETY RELAY BOX, damage to this product will occur.
When you use the SAFETY RELAY BOX, install the SAFETY RELAY BOX to the CONTROLLER.
By doing this, SAFETY RELAY BOX is grounded and the system will be protected against
electric shock.
CAUTION
When connecting the Relay Cord Plug and Emergency Stop Cord Plug, secure the Fastening Ring
fi rmly. If the connection is not made correctly, an intermittent malfunction can occur.
・ Install the SAFETY RELAY BOX to one of the CONTROLLER side faces.
・ Installing the SAFETY RELAY BOX, using the mounting screws (4pcs.) attached to the CONTROLLER side
face (Fig. 4).
① Remove the Mounting Screws (4pcs.) from side of the CONTROLLER.
Mounting Screw
② Install the SAFETY RELAY BOX to the side of CONTROLLER by using removed Mounting Screws (4pcs.) (Fig. 5).
Mounting
Screw
12
Mounting Screw (each 4pcs.) attached to the side of
the CONTROLLER.
E4000 CONTROLLER
E4000 CONTROLLER
E4000
E4000
SAFETY RELAY BOX
SAFETY RELAY BOX
* Attach the SAFETY RELAY BOX to the E4000 CONTROLLER
using the removed Mounting Screw.
Fig. 4
Fig. 5
Mounting Screw
Mounting
Screw