Specifications And Dimensions - Nakanishi E4000 - SRB Operation Manual

Safety relay box
Table of Contents

Advertisement

2 . FEATURES
① Install the SAFETY RELAY BOX to the CONTROLLER for use the SAFETY RELAY BOX. The Safety Relay
"a" contacts switch the Motor Power Line and "b" (*1) contacts switch the external outputs to the machining
center's CNC controller.
② The Safety Relay utilizes Normally Open contacts. The Emergency Stop Signal lines must be supplied with
power to hold the Safety Relay contacts closed and allow the CONTROLLER to supply power to the motor.
Any system errors, trouble with the machining center or the connections between the CONTROLLER and the
machining center's controller will cause the relay contacts to open and the motor to stop.
③ The Emergency Stop Signal Input can be connected to any and all portions of the machine's safety systems
(E-Stop String) to stop the motor any time that stoppage of the spindle and motor is required.
④ The "b" contact outputs can be used to detect an open circuit on the motor line and integrated with the
machines safety systems to stop the machine in case a problem occurs.
*1 : The Safety Relay "b" shows SAFE-1A, SAFE-1B, SAFE-2A and SAFE-2B of External Input / Output
Connector B.

3 . SPECIFICATIONS AND DIMENSIONS

3 - 1 Specifications
Product Name
Model
Applicable CONTROLLER
Weight
・ Relay Cord (Motor Power Line) ・・1pc.
・ Connector Cover ・・2pcs.
・ Operation Manual ・・1set.
* Connector Cap and Connector Cover are attached to the each connector on the SAFETY RELAY BOX.
3 - 2 Outside View
① SAFETY RELAY BOX main body
10
E4000 SAFETY RELAY BOX
E4000 - SRB
E4000 CONTROLLER
850g (Main Body Only)
Standard Accessories
35
10
Fig. 1
・ Emergency Stop Cord・・1pc.
・ Connector Cap ・・1pc.
139
274
254
2- 4.5