  • Page 1 Smart IoT Gateway - iConnector USER GUIDE FOR ICONNECTOR 3G INTEGRATED WIRELESS CO-ORDINATOR STHC-ISG02DB-WS433-CL-04...
  • Page 2 2. Introduction STHC is a Smart IoT Gateway, aka iConnector, a main component in any IoT application. iConnector has a role to connect the real World's things like sensors, meters, ,machines...to server system for data logging, data analytics, monitoring & controls... This iConnector is build-in a wireless co-ordinator in a wireless sensor network, a high- performance type to facilitate remote configuration and diagnostics, as well as remote monitoring and control via any...
  • Page 3: Specification

    RF frequency band datasheets) ETSI EN 300 220, EN 303 204 (Europe) FCC CFR47 Part15 (US), ARIB STD- Ready to comply T108 (Japan)** Vietnam Type Approval Certification QCVN 73:2013/BTTTT, QCVN 96:2015/BTTTT (DAVITEQ B00122019) Security Standard AES-128 Operating temperature -40oC..+85oC SIM slot...
  • Page 4: Product Pictures

    Box dimension W160 x D150 x H100 mm Gross weight < 300g 4. Product Pictures...
  • Page 5: Operation Principle

    5. Operation Principle After the power supply will have 5 minutes to add nodes (value enb_auto_add_sensors = 1 in 5 minutes then = 0), push button function and hall sensor are only available in the first 5 minutes Push Button or Hall sensor for the first 5 minutes when power is available: Press and hold the push button or bring the magnet near the Hall sensor for 2s =>...
  • Page 6 Step 1: After supplying the Co-ordinator, the Node ID must be registered within the first 5 minutes, up to 40 WS Step 2: Take off the wireless sensor battery, then wait for 5s, then insert the battery again Step 3: Bring the wireless sensor closer to the Co-ordinator's antenna, if: Buzzer plays 1 peep sound, that means, registering Node ID on Co-ordinator successfully Buzzer plays 2 peep sounds that this Node ID is already registered 2.
  • Page 7 data node 9 data node 10 data node 11 data node 12 data node 13 data node 14 data node 15 data node 16 data node 17 data node 18 data node 19 data node 20 data node 21 data node 22 data node 23 data node 24 data node 25...
  • Page 8 2024 ctrl node 4 2032 ctrl node 5 2040 ctrl node 6 2048 ctrl node 7 2056 ctrl node 8 2064 ctrl node 9 2072 ctrl node 10 2080 ctrl node 11 2088 ctrl node 12 2096 ctrl node 13 2104 ctrl node 14 2112...
  • Page 9 ==> sync status = 0: sync configuration OK ==> user should read this configuration again to check if it's correct or 6. Configuration First, you need to prepare 6.1 Reset sensor and iConnector sensor node Step 1: Connect Antenna, RS485 - configuration cable and power supply co-ordinator...
  • Page 10 Step 2: Put the magnet closer to the icon on iConnector until you hear "peep" 3 times to reset (2 times for 625 kps option) Step 3: Take off the sensor cover and press the button until you see LED flashes 3 times to reset (2 times for 625 kps option) 6.2 Add sensor nodes...
  • Page 11: Modbus Communication

    Stop bits: 1 Memmap resgisters You can download Modbus Memmap of WS433-CL-FW_V1.9 with the following link: http://filerun.daviteq.com/wl/?id=q64HsdUTIamRdNWIIi7kiBdrcJbmhCkX 7. Installation 7.1 Mounting bracket installation The mounting bracket is made from hard metallic material. Following to these steps as the below picture...
  • Page 12: Installation Location

    7.2 Installation location To maximize the distance of transmission, the ideal condition is Line-of-sight ( L OS) between the two modules. In real life, there is no LOS condition. However, the two modules still communicate each other, but the distance will be reduced significantly.
  • Page 13: Troubleshooting

    Check the configuration of slave Configuration slave address, address, baudrate, parity Cannot read modbus baudrate, parity is not iConnector only supports modbus correct 3, 4, and 16. Check if the value of Reading the wrong modbus status returned by 2 or 3 command, wrong address is an incorrect address reading.
  • Page 14: Support Contacts

    Check the FW of WS433-CL in Read modbus normal The modbus 4 command iConnector if it is older than 1.9 health values but read only supports FW 1.9, old then use command 3 to read data...