ECO OPERATION

9
To automatically control room temperature to save energy (except in DRY and
FAN ONLY mode)
Press
: Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation the set temperature will decrease.
FIREPLACE AND 8°C HEATING OPERATION
10
Fireplace Operation (
)
Keep indoor unit's fan blowing continuously during thermo off, to circulate heat
from other sources over the room. There are three setting parameters: Default
setting > Fireplace 1 > Fireplace 2
Fireplace 1:
During thermo off period, the indoor unit's fan will continue to run by the same
speed, previously selected by end-user.
Fireplace 2:
During thermo off period, the indoor unit's fan will continue to run at super-low
speed, programmed from factory.
8°C Heating Operation (8°C)
Heat mode operation for keep room temperature (5-13°C) with less of energy
usage.
Fireplace and 8°C Heating Operation
FIREPLACE 1
Note:
• While Fireplace operation on heating mode, indoor unit fan always runs
and cold air breezing might be occurred.
• Fireplace and 8°C will operate in Heating mode only.

COMFORT SLEEP OPERATION

11
For comfortable sleep, automatically control air flow and automatically turn
OFF (Except in DRY mode).
1. Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
2. Press
to cancel the comfort sleep operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
HADA CARE FLOW AND AIR FLOW OPEATION
12
HADA CARE FLOW
Air flow upward to the ceiling, provide Indirect air flow to body and
homogenize room temperature.
AIR FLOW
Comfortable air flow can select from this feature.
HADA CARE FLOW and AIR FLOW operation
Press
HADA CARE FLOW
Cancel
Air Flow
Note :
• During HADA CARE FLOW mode, FIX and SWING button cannot active
1120650271-00_S01_182x257_16p_S_p70_190906_EN,TR.indd 5
8°C
FIREPLACE 2
Normal
operation
For start operation as sequence below
Wide left
Wide right
Wide center
Spot left
Spot right
Spot center
POWER-SELECTION AND SILENT
13
OPERATION (OUTDOOR UNIT)
Power-Selection
(
)
This function is used when the circuit breaker is shared with other electrical
appliances. It limits the maximum current and power consumption to 100%,
75%, or 50% and can be implemented by POWER-SELECTION. The lower
percentage, the higher saving and also longer compressor lifetime.
Note:
• When the level is selected, POWER-SEL level flashes on remote LCD
display for 3 seconds.
In case of 75% and 50% level, number "75" or "50" also flashes for 2
seconds.
• Due to the reason that POWER-SELECTION function limits the
maximum current, inadequate cooling or heating capacity may occur.
Silent Operation (
)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the heating capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still prioritized to
ensure having sufficient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit's sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit
by 4 dB(A).
Note:
• While activating of Silent operation, inadequate heating (or cooling)
capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit)

[100%]
SILENT#2

TIMER OPERATION

14
Set the timer when the air conditioner is operating.
Setting the ON Timer
Press
: Set the desired ON
1
timer
2
Press
: Set the timer.
3
Press
: Cancel the timer.
Note :
• Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
• The setting will be saved for the next same operation.

PRESET OPERATION

15
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airflow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The
mark displays.
3. Press
: Operate the preset operation.
EN
[75%]
[50%]
SILENT#1
Setting the OFF Timer
Press
: Set the desired
OFF timer
Press
: Set the timer.
Press
: Cancel the timer.
23/12/2562 13:25:50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents