Carrier Omnizone 50BVC Installation, Start-Up, Service And Controls Operation And Troubleshooting page 33

Water-cooled indoor self-contained systems
Table of Contents

Advertisement

AIRFLOW
2.2
(CFM)
RPM
WATTS
15,000
886
4,444
16,000
893
4,924
17,000
903
5,495
18,000
912
6,095
18,500
919
6,359
19,000
925
6,690
19,500
932
7,048
20,000
940
7,423
20,500
946
7,798
21,000
955
8,199
22,000
971
8,913
23,000
988
9,812
24,000
1006
10,771
AIRFLOW
3.2
(CFM)
RPM
WATTS
15,000
16,000
17,000
1062
7,005
18,000
1065
7,606
18,500
1069
7,946
19,000
1071
8,286
19,500
1076
8,518
20,000
1081
8,904
20,500
1084
9,298
21,000
1090
9,718
22,000
1102
10,608
23,000
1115
11,558
24,000
1128
12,585
LEGEND
Bhp
— Brake Horsepower Input to Supply Fan
Watts — Input Power to Supply Fan Motor
NOTES:
1. Unit is available with the following motor and drive combina-
tions: 7.5, 10, 15, 20 hp standard drive; 7.5, 10, 15, 20 hp
medium-static drive; 7.5, 10, 15, 20 hp high-static drive.
For 7.5 hp standard drives, the drive range is 780 to 960 rpm.
For 10, 15, 20 hp standard and 7.5 hp medium-static drives, the
drive range is 805 to 991 rpm. For 10, 15, 20 hp medium-static
and 7.5 hp high-static drives the drive range is 960 to
1146 rpm. For 10, 15, 20 hp high-static drives the drive range is
1119 to 1335 rpm.
Table 22 — Fan Performance — 50BVT,V054 (cont)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.4
BHP
RPM
WATTS
BHP
5.27
922
4,741
5.62
5.84
927
5,212
6.18
6.52
935
5,795
6.87
7.23
943
6,324
7.59
7.63
950
6,664
8.00
8.03
955
6,996
8.39
8.46
962
7,362
8.83
8.91
969
7,746
9.29
9.36
975
8,121
9.74
9.84
982
8,390
10.23
10.87
998
9,238
11.27
11.97
1014
10,155
12.39
13.14
1031
11,130
13.58
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
3.4
BHP
RPM
WATTS
BHP
8.40
1093
7,353
8.82
9.13
1095
7,946
9.53
9.53
1098
8,286
9.94
9.94
1100
8,493
10.36
10.39
1104
8,861
10.81
10.86
1108
9,247
11.28
11.34
1112
9,641
11.76
11.85
1116
10,060
12.27
12.94
1127
10,959
13.37
14.10
1139
11,918
14.54
15.35
1152
12,953
15.80
2.6
RPM
WATTS
BHP
RPM
958
5,046
5.99
993
961
5,539
6.57
994
967
6,095
7.23
999
974
6,629
7.95
1005
980
6,970
8.36
1010
984
7,310
8.77
1013
991
7,676
9.21
1019
997
8,060
9.67
1025
1003
8,304
10.13
1030
1010
8,715
10.63
1037
1024
9,572
11.68
1050
1040
10,506
12.82
1065
1056
11,490
14.02
1080
3.6
RPM
WATTS
BHP
RPM
1127
8,501
10.37
1156
1128
8,835
10.78
1157
1132
9,212
11.24
1159
1136
9,598
11.71
1163
1138
9,992
12.19
1165
1143
10,411
12.70
1169
1153
11,319
13.81
1178
1164
12,286
14.99
1188
1176
13,329
16.26
1200
2. Italics indicates field-supplied drive required.
3.
Do not operate in shaded area.
4. Static pressure losses must be applied to external static pres-
sure before entering the fan performance table.
5. Interpolation is permitted: extrapolation is not.
6. Fan performance is based on filter, unit casing, and wet coil
losses.
7. Bhp values are per fan. Watts values are per motor. Unit has
2 supply fans and 2 motors.
33
2.8
3.0
WATTS
BHP
RPM
WATTS
5,380
6.38
5,857
6.95
6,341
7.61
1031
6,664
6,943
8.33
1035
7,266
7,284
8.74
1039
7,606
7,624
9.15
1042
7,955
7,999
9.60
1047
8,330
8,253
10.07
1053
8,578
8,630
10.53
1057
8,955
9,041
11.03
1063
9,375
9,915
12.09
1076
10,257
10,848
13.23
1090
11,207
11,849
14.45
1104
12,217
3.8
4.0
WATTS
BHP
RPM
WATTS
8,861
10.81
9,195
11.22
1185
9,564
9,572
11.68
1187
9,932
9,958
12.15
1190
10,326
10,343
12.62
1191
10,711
10,771
13.14
1195
11,139
11,678
14.25
1203
12,046
12,653
15.43
1212
13,038
13,705
16.72
1223
14,090
BHP
8.00
8.72
9.13
9.54
9.99
10.46
10.92
11.44
12.51
13.67
14.90
BHP
11.67
12.12
12.60
13.07
13.59
14.69
15.90
17.19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents