VARIOUS IN/OUTPUT SETTING
iMDC is equipped with maximum of 128 input ports and 128 output ports.
- Input port type setting: You can specify whether the format of the input signal is
blocked (NO) or connected (NC) in normal operation. Various input devices you w
ant to use can be connected by specifying NO or NC status.
- Input type setting: you can use the input ports to receive signal from the exit butt
on and the fire sensor and the door open sensor.
- Output type setting: Output type is Relay output and you can set the output time
for output ports.
VARIOUS READER MODE SETTING
The reader connected from iMDC has various operation modes.
- RF Card Only: Only RF card is necessary to grant access.
- PIN Only: Only PIN (keypad) is necessary to grant access.
- RF Card + PW: Both RF card and password are necessary to grant access.
DATA AND EVENT UP/DOWNLOAD
User data, event information and setting values are downloaded / uploaded from/to t
he host computer by application software, STARWATCH ENTERPRISE.
DOOR SETTING
iMDC offers interfaces of 32 RF readers; therefore the number of controlled doors ca
n be up to 32ea. In this case, exit button must be used to exit from inside. Also entran
ce and exit reader can be set to the each doors, in this case, maximum of doors to co
ntrol are 16. If you want to use the function' ANTI PASSBACK, entrance/exit reader ha
s to be installed to each door.
iMDC has maximum of 128 relay output and TTL input ports. The lock device of each
door is controlled by relay and Exit input, Door contact sensor are by TTL Input.
iMDC can set the Exit button and Door contact sensor input to each door. And you ca
n set the door open time alarm function, forced door open alarm function by using d
oor contact sensor