Brigantia 57-DVRS50N User's Installation, Operation And Maintenance Manual

Direct vent gas fireplace heater

Advertisement

Quick Links

WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
- Do not store or use gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any
phone in your building
• Leave the building immediately
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppliers
instructions
• If you can not reach your gas supplier, call the fire
department
- Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Archgard Fireplace Products
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
57-DVRS50N
Fireplace Heater
SERIAL NUMBERS 510083 AND HIGHER
U
SERS'
O
PERATION and
M
AINTENANCE
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
Gas Fireplace Efficiency Rating
72.74%
Based on CSA P.4.1-15
Direct Vent Gas
I
NSTALLATION
M
ANUAL
200-0057-08
June 07 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 57-DVRS50N and is the answer not in the manual?

Questions and answers

Summary of Contents for Brigantia 57-DVRS50N

  • Page 1 57-DVRS50N Direct Vent Gas Fireplace Heater SERIAL NUMBERS 510083 AND HIGHER SERS’ NSTALLATION PERATION and AINTENANCE ANUAL This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Caution and Safety Instructions Appliance Certification, Installation Codes and Specifications Rating Plate Appliance Dimensions Framing Dimensions and Clearance to Combustibles 10-12 Installation Instructions 13-17 Venting Instructions Gas Connections Panel & Baffle installation 20-22 Burner media, Door, Screen, and Surround Installation Checking Inlet &...
  • Page 3 INTRODUCTION Congratulations on choosing an Brigantia fireplace! The 57-DVRS50N is one of the most advanced direct vent fireplace heaters available. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you with an appliance for many trouble-free years of reliable service.
  • Page 4: Rating Plate

    57-DVRS50N RATING PLATE...
  • Page 5 57-DVRS50N Installation Checklist This standard installation checklist is to be used by the installer in conjunction with, not instead of, the instructions contained within this installation manual. Customer: Date Installed: Install Address: Location of Fireplace: Installer: Appliance Install: IF NO, WHY NOT? Standoffs and side nailing flanges are installed.
  • Page 6 57-DVRS50N Safety Information Caution FOR YOUR SAFETY - Do not install or operate your 57-DVRS50N without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the warranty and may prove hazardous. • This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes •...
  • Page 7 57-DVRS50N APPLIANCE CERTIFICATION This appliance was listed by QAI Laboratories Inc to the following USA and Canadian gas appliance standards. - ANSI Z21.88-2017/CSA 2.33-2017 Vented Gas Fireplace Heaters - CSA P.4.1-15 Testing method for measuring annual fireplace efficiency. - CSA C22.2 No.3 – M1988(R.2014) – Electrical Features of Fuel-Burning Equipment Commonwealth of Massachusetts: This appliance has been manufactured in accordance with Massachusetts code 248 CMR 5.00.
  • Page 8: Appliance Dimensions

    57-DVRS50N APPLIANCE DIMENSIONS Surround Attached Surround Removed...
  • Page 9 57-DVRS50N Framing Dimensions The following section describes the requirements for framing for the model 57-DVRS50N. Note: Framing should be constructed as required by local building codes 2 x 6 Framing, opening in framing should be minimum of 66.50”W x 42.00”H.
  • Page 10 57-DVRS50N Corner Install View Figure 3 Mantle Clearances Room Ceiling Clearance to Combustibles Minimum measurements below are from the edge of door (unless otherwise noted). Inches Top - to standoffs 0” Top of Door Sides-to standoffs 0” Adjacent Side Wall 18”...
  • Page 11: Installation Instructions

    57-DVRS50N Installation Instructions Figure 5 Stand-off 999-DV-8HTCL Maximum 6” Horizontal run when using the basic 999-DV-8HTCL Termination. Used only when there is a direct connection to the unit The 999-DV-8HTCLT termination allows the horizontal run to a maximum of 32”.
  • Page 12 57-DVRS50N Installation Instructions Frame opening and cut out hole for the termination and thimble as shown in fig. #6 Figure 6 When installing on an exterior wall you must install the exterior wall insula- tion board (#57-IB). Place insulation board with the foil facing into the room.
  • Page 13 Next install the outer portion of the wall thimble and the termination. N O T E For installations straight off the back of the 57-DVRS50N the Archgard 999-DV-8HTCL termination is required. The maximum horizontal run straight out the back is 6.00”(no rise).
  • Page 14 Note: Only venting systems listed in this manual may be used with the model 57-DVRS50N Planning your vent installation This type of direct vent system may terminate in one of two ways: vertical termination using a vent cap, or horizontally using a wall termination.
  • Page 15 57-DVRS50N Installation Instructions Cont. Horizontal Wall Vent Terminations The position of the horizontal vent termination must be positioned in such a way as to meet all local building codes. Cut and frame the exterior wall to accept the Wall Thimble. Install the Wall Thimble shield using wood screws.
  • Page 16 57-DVRS50N Installation Instructions Cont. Figure 22 – Vent Termination Locations Horizontal Installation regulator. Note: Clearances are to be in accordance The horizontal run must have a 1/4” rise on an exterior wall and with local installation codes and the requirements of must meet all local and national building codes, and must not be the gas supplier.
  • Page 17 57-DVRS50N Installation Instructions Cont. Always maintain a 1” clearance around the vent pipe (vertical) and on horizontal venting 2” clearance on the top of the vent, when passing through ceilings, walls, roofs, enclosures, attic rafters or any combustible surfaces. DO NOT PACK AIR SPACES WITH INSULATION.
  • Page 18 57-DVRS50N Installation Instructions Cont. Maximum Total Venting Length Venting Chart Maximum total venting allowed is 50ft. This would be when configured for 40ft vertical with 10ft horizontal. Maximum vertical vent is 40ft. Maximum horizontal vent is 20ft. Minimum 10ft vertical vent rise required for maximum 20ft horizontal vent run.
  • Page 19: Gas Connections

    57-DVRS50N GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve.
  • Page 20 57-DVRS50N Rear Panel Installation Instructions Hang the left and right side back panel onto the bracket in the back of the firebox. Align with the far outside edge of the brack- Hang the center back panel onto the bracket and slide the two outside panels in until they touch the center panel.
  • Page 21 Silhouette Log Set Installation (Optional) Your Brigantia Fireplace is approved for use with the Optional Silhouette Log Set. The logs come in White, Black, and Grey. Each set comes with 2 logs and you can install a max of 6 logs in your fireplace in any color combination you wish.
  • Page 22 57-DVRS50N Door Installation Install the top of the door so the slots in the door go over the tabs on the spring clips as shown to the right. Swing door down making sure it sits on top of the unit.
  • Page 23 57-DVRS50N Barrier Screen Installation Mounting tabs closer together located • at the top of the screen Mounting tabs located on the corners • at the bottom of the screen. Place bottom tabs on the Top tabs inside edge of door frame Slightly twist top part of screen frame •...
  • Page 24 57-DVRS50N Surround Clip Installation Install the four surround retaining clips so they are pushed back against the facing. Secure in place with the screws provided. See right Surround Installation The surround is held in place by clips buttons (two at the top, two at the bottom). Line up the clips with the fireplace and push until it locks in.
  • Page 25 57-DVRS50N CHECKING INLET AND OUTLET GAS PRESSURE 1. Remove the surround. 2. The pressure test taps are located on the valve. The taps are located in the gas valve front face. The inlet is marked ‘IN’ and the outlet is marked ‘OUT’.
  • Page 26 57-DVRS50N FINAL INSTALLATION CHECK Each Brigantia Gas Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Archgard recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and that the electrical system is in working order.
  • Page 27: Lighting Instructions On Rating Plate

    57-DVRS50N LIGHTING INSTRUCTIONS ON RATING PLATE...
  • Page 28 57-DVRS50N FIRST FIRE When operated for the first few times, the appliance will emit some odor and fumes. This is due to the heat from the appliance evaporating the oils and solvents used in fabricating the appliance. Close off the room to the rest of the house and open all windows. Keep the room well ventilated, as smoke alarm may sound.
  • Page 29: Remote Control Setup And Operation

    57-DVRS50N REMOTE CONTROL SETUP AND OPERATION (future option) SIMPLE INSTALLATION Optional handheld remote...
  • Page 30 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont. N.A. on this unit Future Option ATTENTION TURN OFF THE MAIN GAS SUPPLY DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER DEVICE TURN OFF MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BAT-...
  • Page 31 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont.
  • Page 32 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont.
  • Page 33 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont.
  • Page 34 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont. The unit is shipped from the factory with the ability for IPI/CPI selection active. To disable the Continuous Pilot selection ability, cut one of the wires (blue or white) shown in the picture and cap.
  • Page 35 57-DVRS50N REMOTE CONTROL SETUP AND OPERATION, cont.
  • Page 36: Conversion Kit Instructions

    57-DVRS50N CONVERSION KIT INSTRUCTIONS IMPORTANT: This fireplace is Natural gas ready. If converting to LP gas, follow instructions below KIT NUMBER: 57-CKNG for NAT GAS KIT NUMBER: 57-CKLP for LPG Step # 1 - PREPARATION Remove outer surround and door. Place to the side to prevent them from being damaged.
  • Page 37 57-DVRS50N MAINTENANCE CAUTION: Do not conduct maintenance on the appliance while it is operating or while it is still hot. Always verify proper operation after servicing. Cleaning and Routine Maintenance The exterior painted surfaces, glass, and metal plated trims may be cleaned with a soft, non-abrasive cloth and water or a suitable, mild, non-abrasive cleaner.
  • Page 38 57-DVRS50N CONVERSION KIT INSTRUCTIONS, con’t Step # 7 Valve Conversion...
  • Page 39 57-DVRS50N CONVERSION KIT INSTRUCTIONS, con’t Step # 8 Complete the Conversion Fill out and attach conversion label to the fireplace near the valve Change Rating Plate to show new fuel configuration Reinstall the burners, support plates and baffle by reversing the removal process.
  • Page 40: Wiring Schematics

    57-DVRS50N WIRING SCHEMATIC Figure 25...
  • Page 41: Parts List

    57-DVRS50N PARTS LIST Item # Item Description Unit 308-6011 SIT PROFLAME II CONTROL MODULE Main control module 308-6012 WIRING HARNESS Main wiring for module 308-6016 WIRING HARNESS SPLIT FLOW Split flow wiring harness 308-6013 BATTERY HOLDER AA Battery holder 308-6024...
  • Page 42: Frequently Asked Questions

    57-DVRS50N FREQUENTLY ASKED QUESTIONS Listed below are some frequently asked questions regarding Brigantia Gas Fireplaces. If you have ques- tions that are not listed below, or are not answered in this manual, please contact your Authorized Brig- antia Dealer. Q. My glass has a condensation “fog” when the appliance is first lit.
  • Page 43 This Limited Warranty is made by Archgard Industries, hereinafter referred to as “Brigantia”. Brigantia warrants to the original purchaser of a Brigantia gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use and ser- vice, for a “lifetime”.
  • Page 44: Notes

    57-DVRS50N NOTES...
  • Page 45 57-DVRS50N NOTES...
  • Page 46 57-DVRS50N NOTES...
  • Page 47: Warranty

    POSTAGE WARRANTY REGISTRATION ARCHGARD INDUSTRIES 7116 BEATTY DRIVE MISSION, B.C. CANADA V2V 6B4 FOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED 57-DVRS50N Model # : Serial #: Date Installed: yyyy Name: Address: City: State/Prov: ZIP: Phone: ( _____ ) Dealer's Name &...
  • Page 48 ARCHGARD INDUSTRIES 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com...

This manual is also suitable for:

510083

Table of Contents