Technical Specifications; Before You Start - EBECO Snowmelt Assembly Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Assembly instructions
Thank you for choosing Ebeco. For the guarantee
to be valid, the product must be installed and
operated as indicated in this manual. This means
it is extremely important that you read the entire
manual.
If you have any questions, you are always more
than welcome to contact Ebeco. Call +46 (0) 31
707 75 50 or send an e-mail to support@ebeco.se.

Technical specifications

ART. NO.
POWER
8960280
700 W
8960281
1,100 W
8960282
1,350 W
8960283
2,350 W
8960284
2,900 W

Before you start

• Check that the material supplied corresponds
with the information on the delivery note.
• Measure the insulation and resistance of the mat.
See values in the table. Enter the values in the test
report (at the end of the manual).
• The insulation and resistance of the mat must be
measured before and after embedding/surfacing,
to check that the mat was not damaged when it
was laid. Enter the values in the test report.
• The mat can be covered with paving stones,
flagstones or asphalt (NOTE: Do not lay in hot
asphalt). The mat can also be laid above existing
concrete slabs and embedded.
• We recommend that you use the Ebeco Quick
Board (art. no. 8960150) for a more energy
efficient installation.
• When planning the installation, take into account
the fact that the length of the cold cable is 5 m.
Installing the Ebeco Snowmat
The installation is described using illustrations. See page 10.
WIDTH
AREA
2.1 m ²
0.5 m
3.5 m ²
0.5 m
4.2 m ²
0.5 m
7.2 m ²
0.5 m
9.0 m ²
0.5 m
Feel free to visit ebeco.com for more information.
Important The system is a mains voltage installa-
tion and must therefore be installed in accordance
with the current regulations and under the super-
vision of a qualified electrician.
RESISTANCE
INSULATION
77 Ω
> 10 m Ω
49 Ω
> 10 m Ω
39 Ω
> 10 m Ω
23 Ω
> 10 m Ω
18 Ω
> 10 m Ω Tolerance ± 10 %
• The cold cable splice must be laid in sand/
concrete. The heating cable must not be cut. Only
the cold cable may be shortened.
• The cable must not touch or cross itself.
Minimum distance 60 mm.
• The cable must not cross any expansion joints.
• Plan how any control sensors are to be
positioned. Measuring elements for thermostatic
control are to be laid in a plastic tube under the
mat. Panelboard with temperature/humidity
sensor: refer to the instructions supplied with
the panelboard. Snowmat can also be controlled
using a timer.
• Fill in and affix the heating cable signs for each
junction box. A diagram/photo of the heating mat
installation must be on display in the electrical
distribution centre.