3-2. Multi Flow Duct As (PCB Volum & R-Sensor)
No
3
Remove 4 screws at Locking Points with (+) driver.
4
Hold the "Cover Lamp" and Pull forward the "Multi Flow
Duct As" by the first Locking Points(hook) .
Caution!!
Pull forward at a time, Insu at the back of "Multi Flow
Duct As" may be broken.(Refer to picture of Insu)
5
With both hands, Pull forward "Multi Flow Duct As"
Caution!!
The end of "Multi Flow Duct As" and Ceiling of
Refrigerator not to touch each other.
Procedure
Locking Piont
Insu
No
6
Disconnect wire housing.
7
"Multi Flow Duct A" can be separated by 2 parts.
(Cover & Insu)
The 2 Parts is connected by 4 double-sided tape(
and 2 hooks(
Disassembling PCB Volume & R-sensor
8
PCB Volume
The tape peels off covering on the PCB Volume
20
3. DISASSEMBLY
Procedure
)
R‐Sensor
Harness PCB Volume
Insu
Cover
)