SECTION 2 - ELECTRICAL SUPPLY AND CONNECTION

Electrical ratings are as stated on the unit data plate. This is based on standard UK specification at
230V - 240V~ as appropriate. Wiring must be executed in accordance with the regulations listed in
this booklet.
WARNING! - Each individual appliance must be earthed!
The appliance is also provided with a terminal for the connection of an external
equipotential conductor. This terminal is in effective electrical contact with all fixed
exposed metal parts of the appliance, and shall allow the connection of a conductor
having a nominal cross-sectional area of up to 10 mm². It is located on the rear panel and
is identified by the following label and must only be used for bonding purposes.
After completion of installation, the method of operation should be demonstrated to the kitchen
staff. The isolating switch location, for use in an emergency or during cleaning should also be
pointed out.
LD1 Boiling Top
This model is designed to be connected to a single phase AC supply using the 2 metre mains lead
fitted as standard.
Check that no damage has occurred to the appliance, power cable and plug top during transit. If
damage has occurred do not use the appliance.
Ensure that the mains power cable is routed free from the appliance to avoid damage.
We recommend supplementary electrical protection with the use of a residual current device (RCD).
Periodic testing, repair and fixed wiring connection should only be undertaken by a skilled and
competent electrician.
Wires are coloured in accordance with the following code and should be connected to the plug as
follows:
EARTH to terminal marked E or coloured GREEN or GREEN/YELLOW.
NEUTRAL to terminal marked N or coloured BLACK.
LIVE to terminal marked L or coloured RED.
Units which receive power from a plug, adaptor or distribution board must be individually protected
by a fuse with an appropriate rating.
For models with two mains leads, each lead requires to be protected by a fuse with an appropriate
rating.
Any replacement supply cable must be 1.5mmŽ2•, cord code designation 245 IEC 57 (CENELEC H05
RN-F).
For internal connection, outer sheathing must be stripped 140mm from the cable end. The live and
neutral conductors must be trimmed so that the Earth conductor is longer by 50mm. Pass inlet cable
through the rear panel cord grip and ensure that the cable is routed without leaving excessive free
length inside the appliance.