Specifications - Tripp Lite SM500RMNAFTA Specification Sheet

Smart pro line interactive rack/tower ups - nafta assembled version of smart500rt1u

Advertisement

Includes 6 UPS-supported outlets, with one pair of individually controllable outlets that can be powered off and back on again via software
interface
PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, pager & email
notification, event logging and running user-defined script commands
Offers simultaneous monitoring by up to 3 directly-connected devices through included USB, DB9 and SNMP* interfaces (*requires optional
SNMPWEBCARD), or the monitoring of any number of additional UPS systems over IP with included PowerAlert monitoring software. Free
PowerAlert enterprise management software is also available for select opportunities
Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage,
DC battery voltage and remaining battery capacity
Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for scheduled or immediate
reboot of connected devices
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating
systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again (requires
optional WATCHDOGSW)
Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter
Emergency Power Off (EPO) interface with cable
Multi-function audible alarms and set of 5 front panel LEDs
Network-grade AC surge suppression
Attractive all-black color scheme
UPS battery set ships fully assembled and ready for installation, no time consuming connection of internal batteries by user is necessary
$250,000
connected equipment insurance

Specifications

OUTPUT
Output Volt Amp
Capacity (VA)
Output Watt Capacity
(watts)
Output power factor
Nominal Output
Voltage(s) Supported
Frequency compatibility
Output voltage
regulation (line mode)
Output voltage
regulation (Battery mode)
Built-in UPS output
receptacles
Built-in controllable
switched load banks
Basic PDU options
Metered PDU options
Switched PDU options
External PDU
redundancy options
Output AC waveform (AC
mode)
Output AC waveform
(battery mode)
(USA and Canada Only)
500
300
0.6
120V
60 Hz
-15%, +13%
+/- 5%
7 5-15R outlet(s)
One switchable single-outlet 5-15R load bank
PDU1215
(1U / 13 5-15R outlets);
PDUV15
(0U / 12 5-15R outlets)
PDUMH15
(1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*;
PDUMH15ATNET
(1U / 8 5-15R outlets)*;
*Auto Transfer Switch features utilizing the secondary PDU input cord are compatible with Smart Online UPS
models only
Sine wave
PWM sine wave
PDUNV
(1U / 2 C19, 12 C13 outlets);
PDUMV15NET
(0U / 16 5-15R outlets)
PDU1415
(0U / 14 5-15R outlets);
PDUMV15
(0U / 16 5-15R outlets)