Lubricator 43, Lubricator 1300
Check the oil level.
Check the valve cone (A), by first removing the
stop screw (B) and then inserting a pin into the
hole. Switch the air system on and off and feel if
the valve cone (A) is opening and closing
correctly. If the valve cone (A) is not working
correctly, disconnect the lubricator from the
compressed air line and bleed the oil chamber by
loosening the filler plug (F).
Remove the spring pin (C), oil dosage screw (D)
and valve cone (A). Clean the components and if
necessary, change the O-rings. When
reassembling, make sure that the spring pin (C)
is fitted.
Make sure that the check valve (E) is sealing
effectively, if not, clean or replace the check valve
(E).
Check for leakage around the filler plug (F).
Make sure that there is no dirt in the oil chamber
(G).
9800 1218 90 | Original instructions
Safety and operating instructions
Storage
>
Clean the lubricator properly before storage, in
order to avoid hazardous substances.
>
If the lubricator is stored filled with oil, place it
with the filler plug upwards to prevent oil from
leaking out through the mouth of the air pipe.
>
Always store the lubricator in a dry place.
Disposal
A used machine must be treated and disposed of in
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.