16
07 INSTRUCTIONS FOR GENERAL USE

FAULT-FINDING AND RECTIFICATION

What
The front wheels do not
run in a straight line.
The rollator is hard to
push.
The brake function is
insufficient or uneven.
The seat cover is not taut
or not firmly connected to
the rollator.
Squeaking or grinding
noises
The rollator does not
provide secure support or
does not stand reliably.
DIETZ / User manual rollator TAiMA M-GT, S-GT, M-ECO / Version 3.0.1 EN
Possible causes
The wheel bearings are defective or
the wheel suspension is no longer
correctly attached.
The wheel axles/wheel hubs are dirty.
The brakes are incorrectly adjusted.
The wheel bearings are defective or
the wheel suspension is no longer
correctly attached.
The brakes are incorrectly adjusted or
the brake pad has worn out.
The rollator is not fully unfolded.
The seat cover is not correctly fixed in
the side rails or is defective.
The cross struts or folding mechanism
are defective.
Various causes
The push handles are not fixed in
place properly or have been incorrectly
adjusted for the user.
The rollator has not been fully
unfolded and the folding lock has not
been engaged.
The rollator frame or the push handles
are damaged.
Measures
Consult an authorised specialist
retailer.
Remove the dirt.
Consult an authorised specialist
retailer.
Consult an authorised specialist
retailer.
Fully unfold the rollator and engage
the folding lock.
Consult an authorised specialist
retailer.
Consult an authorised specialist
retailer.
Check the position of the push
handles.
Check whether the clamping levers
on the push handles are securely
tightened.
Fully unfold the rollator and engage
the folding lock.
Consult an authorised specialist
retailer.