Shutdown of system up
to 6 months
Disconnect the living
area battery from the
12 V power supply
Shutdown period longer
than 6 months
811.573 BA / EN
Instruction Manual Electrobloc EBL 226 C +OVP
If the device becomes too hot due to excessive ambient temperature or
Y
lack of ventilation, the charging current is automatically reduced. Nevert-
heless, always prevent the device from overheating.
If the automatic shutdown mechanism of the battery monitor is triggered,
Y
fully charge the living area battery.
3.4

Closing down the System

ATTENTION!
Y
Total discharge.
Damage to the living area battery:
Fully charge the living area battery before and after closing down the
F
system. (Connect a vehicle with an 80 Ah battery and a vehicle with a
160 Ah battery to the mains for at least 12 and 24 hours respectively).
ATTENTION!
Y
Permitted input voltages exceeded.
Damage to connected consumers:
Do not operate any connected Schaudt solar charge regulator without
F
battery.
If the battery is going to be changed or removed, first remove "+ solar
F
cell" connector on the solar charge regulator.
Fully charge the living area battery before closing down the system.
The living area battery is then protected against total discharge. This only
applies if the battery is intact. Follow the instructions of the battery manufac-
turer. The shut down system requires approx. 4 Ah per month.
Disconnect the living area battery from the 12 V power supply if you are not
going to use the motorhome for a longer period (during the winter for exam-
ple). For this, the system has a battery cut-off mechanism that isolates the
living area battery from the vehicle. The battery cut-off is enabled on the
DT/LT ... control and switch panel (see operating manual of DT/LT ... control
and switch panel).
Switch off the main switch on the DT/LT ... control and switch panel.
Enable the battery cut-off on the DT/LT ... control and switch panel (see
operating manual of DT/LT ... control and switch panel).
The living area battery can also be charged using the internal charger
Y
module, an auxiliary battery charging unit, the solar charge regulator and
the alternator when the battery cut-off switch is switched off.
Fully charge the living area battery before closing down the system.
Remove the "+ solar cell" connector on the solar charge regulator.
Remove the clamps from the battery poles.
The battery alarm is no longer active.
Y
The frost protection valve opens for certain heater systems when the li-
Y
ving area battery is isolated from the Electroblock via the battery cut-off.
The boiler and water tank empty when the frost protection valve is open.
For more information, see the instruction manual of the heater system.
Date: 30.09.2009