5. OPERATION

5-1. Tune ON the power

Fig. 1

5-2. Starting the air supply

1) Insert the power cord plug into the socket
(supply voltage: 220 V ± 20 %, 50 Hz). Be
sure to ground the power cord for the sake of
safety.
2) Among the power switches (air switches) in
the control panel cabinet, the switch that is
located at the left side of the control panel and
has the identical-color upper and lower cords
(red and red, and black and black) is the laser
power supply switch ❶ . (See Fig. 1.) Another
air switch that is located at the upper right cor-
ner in the control panel and has different-color
upper and lower cords (red and brown, and
blue and black) is the sewing machine power
supply air switch ❷ . (See Fig. 2.)
Put the compressed air from the air source (air
pressure: 0.5 - 0.6 MPa) to the air supply suction
inlet 64 by means of the air tube (specification: 8
× 5 mm).