F
H
I
4) Connect the current indication meter connec-
tor to the laser power supply cord connector.
Insert laser power supply connection connec-
tor 2 G into the current indication meter (See
the figure on the left).
G
5) Put 2.5-L pure water or distilled water in the
cooling system. Use of tap water or mineral
water is prohibited. (Refer to
feed water to the cooling system, and water
changing cycle" p.12
in the cooling system.)
J
– 9 –
F: Current indication meter connector (2P
male terminal)
G : Laser power supply connection connector
2 (2P female terminal)
H : Current indication meter connecting wire
I : Current indication meter
J : Laser power supply connecting wire 2