ADC Digivance NXD Installation And Maintenance Manual page 67

Radio access node (ran)
Hide thumbs Also See for Digivance NXD:
Table of Contents

Advertisement

• Three nuts, three flat washers, three 3 in. square curved washers, and three split ring
washers for bolts
Materials Required, ADC Supplied:
• RAN fixturing angle P/N 1001509P001 (X2)
• 1/4-20 X 3/4 hex bolts (X4)
• 2 in. through hull bulkhead fitting
• Flexible grommet
Use the following procedure to install an expansion RAN. Refer to
Note: This procedure assumes that the expansion RAN is installed on a utility pole
directly above the existing RAN.
1. Open the existing RAN door.
2. Remove the solar shield from the existing RAN. Refer to the solar shield installation
procedure in
Section 2.7.1 on Page 43
and do the steps in a reverse order.
2 IN. (5.08 CM)
BULKHEAD FITTING
SUPPLIED WITH
EXTENSION RAN
1.50 IN.
(3.8 CM)
KENNARD
FLEXIBLE GROMMET
SUPPLIED WITH
EXTENSION RAN
Figure 39. Dual RAN Pole Mount
ADCP-75-210 • Issue 1 • March 2007
Figure
39.
21296-A
Page 55
© 2007, ADC Telecommunications, Inc.