(2) Cleaning the Singlet core units (SCUs):
After every 200-250 hours of operation the 2 Singlet core units (SCUs) should
be washed and cleaned.
For cleaning the Singlet core units (SCU), please follow the instructions:
1. Remove the dust filter housing (Fig.1) by releasing two screws on its top side.
2. Disconnect the electrical plug of each one of the two SCUs.
3. Open and release the two nuts from each SCU.
4. Gently slide out each SCU from its two supporting (long) screws*.
5. Wash each SCU with tap water (Fig.3) and clean it up to remove dust and dirt.
6. Dry the SCU or gently wipe it with soft cloth.
7. Slide back the SCUs on their supporting screws and tight them with their nuts.
Make sure the SCUs are directed correctly according to the signs.
Note:
8. Reconnect the electrical plugs of the two SCUs.
9. Place the dust filter housing back to its position and tight it by its two screws.
(*) Warning:
The glass tubes of the SCUs are very fragile and must be treated gently.
Do not touch the glass tubes by hand and do not scratch them.