Download Print this page
Hide thumbs Also See for ActivO:

Advertisement

Quick Links

Activ0Tm
User Manual
North America
for
Activated by
Air Marketing Group LLC
141 kinclerkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: www.amgaircorn Email: info@amgaircom

Advertisement

loading

Summary of Contents for ecozone ActivO

  • Page 1 Activ0Tm User Manual North America Activated by Air Marketing Group LLC 141 kinclerkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: www.amgaircorn Email: info@amgaircom...
  • Page 2: Table Of Contents

    Unpacking ....................General Information ................Declaration of Conformity ................4 Safety Precautions & Warnings ............. The ActivO control panel and other indicators ......... Technical Specifications ................Operation ......................8 Controller settings ................Activation, Deactivation and Total Operating Time .....
  • Page 3 Ecozone's Activ0 is a mobile and easy-to-use deodorizing system for indoor use. This robust computer controlled automatic system is characterized by high safety standards. The system incorporates ECOZONE's unique ADA system. a double-stage operating cycle that creates ozone and subsequently removes it, allowing the immediate reoccupation of treated spaces.
  • Page 4 Reglages tactles pourrait se renverser et blesser. Placez toujours une sangle de Is temperature Logement autour du bother du modele EB1400, pour le tenir en place sur arriere sortie d'air (ensemble de le chariot Unimover ou le chariot manual pendant le transport processus (la fiktre locafise fraiche)
  • Page 5: The Activo Control Panel And Other Indicators

    The Activ0 control panel and other indicators Room Size Refine Time Hard Reset Stop / Reset 4" Air Outlet (lid. Flashing: Olieration Air Marketing Group LLC 141 kinclerkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: www.amgaircorn Email: info@amgaircom...
  • Page 6: Technical Specifications

    The Activ0 system is a portable high-duty and rugged system. It features the most advanced technology in the field of odour- control and air-treatment. The Activ0 employs Ecozone's state-of-the-art and patented Singlet Unit which is characterized by relatively high activation rate and enhanced reliability.
  • Page 7 Indoor use only Temperature: 25 °F to 120 Humidity: maximum relative humidity: 95%; ECOZONE Technologies has a policy of continuous product improvement and reserves the right to modify or change this specification at any time without notice. hi 411, 1.11P...
  • Page 8: Operation

    INDICATING THAT TILE MAC/IINE IS NO LONGER IN OPERATION. DO NOT ATTEMPT TO ENTER THE ROOM WHILE MACHINE IS IN OPERATION; VENTILATE ROOM AFTER USE Connect power cord to socket on ActivO's rear panel (bottom) and on!) then connect it to the power source socket. Controller settings Air Marketing Group LLC 141 kinclerkarnack Rd.
  • Page 9 Press the 'STOP (Red) button to Reset. The display will present a code followed by the alternating Ready Set Room Size. prompt: • Select 'Room Size' by pressing the respective keypad button. Note: You may choose between the following 4 room sizes: Small: for room volumes below 1 000i13.
  • Page 10 Short Cycle-Time (Light odor) Intermediate Cycle-Time (Average odor) Long Cycle-Time (Strong odor) Down 0 Reline Time setting (optional) by pressing the blue-arrow buttons to extend or to shorten the operation cycle time, respectively. Please refer to reference chart on page-13. Note: Time is indicated on LCD in hours and minutes.
  • Page 11 green (I) START. 0 Press button for Before starting operation verify that the treated area has been vacated of people, animals, plants and items containing natural rubber EXAMPLES OF USE OF ITEMS CONTAINING NATURAL RUBBER Items made of natural rubber (gum) are many and differ in their rubber content; the more rubber content.
  • Page 12 SPECIFICATIONS MAINTENANCE CMC 100 Dehumidifier WARNING! Unplug unit before cleaning or servicing Name Model F391-A Note: Protect from freezing. Freezing may damage unit 24 in Dimensions (W x H x D) Note: Check filter one month after first installation for any initial 25.4 35.6 61 cm...
  • Page 13 In the event indications do not correspond to the above, leave the room immediately and call for ECOZONE service. • After the operation has ended and before moving the machine elsewhere, be sure to disconnect the tiower cord from the power socket.
  • Page 14: Activation, Deactivation And Total Operating Time

    Activation, Deactivation and Total Operating Times Generation Time Decomposition Total Cycle Time = Default Default Default Inter Intermediate Short Inter Long Time (minutes) Room Volume Small (<1000ft Medium (<2000ft Large (<3500ft 1440 1318 X-Large (>3500ft 2880 2698 *lag Keyboard Controlled Maximum Change From Default Time Down Inter Short...
  • Page 15: Maintenance And Service

    'Needs Service'. If you have a 'good pair of hands and follow these instructions carefully. this 3-step procedure should take you about 1 hour. CAUTION DISCONNECT POWER FROM THE ACTIVO BEFORE BEGINNING PROCEDURE BEGINS NEXT PAGE 421.410 Alt illetrivallag Gump (IC Air Marketing Group LLC 141 kinclerkarnack Rd.
  • Page 16 Step 1 Clean Dust Filter (#25 in picture at bottom of this page) a. Remove black front grill panel 026) by unscrewing 6 screws. What you will then see is shown in the picture at the bottom of this page. b.
  • Page 17 Steu 2 Clean Ozone Generating Cores (Singlets) (#15 below) a. There are two (2) Singlets to remove and clean. They are shown side by side as in this picture: SIFigk PentiiRocl 2 Nots for Singki Ozone 1-ilteli.112 unit # 17 2 HA' 31 R...-ro.1/4, for Filtering tin!' b.
  • Page 18 Dri-Eaz Airmover Specifications Model -A F351 F352 F350 F259 F174-BLU F367 Height 18.8" 47.8 18.8'' / 47.8 18.8'' / 47.8 24'' / 61 cm 19.2" 25.9" 65.8 cm Width 17" 43.2 cm 17" / 43.2 cm 17" 43.2 cm 20.3" 51.5 18.7"...
  • Page 19: Troubleshooting

    "Needs Service" of use. Upon notification, please refer to Section 6 above, page 15. Call local ECOZONE distributor for technical Other support. Air Marketing Group LLC 141 kinclerkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: www.amgaircorn Email: info@amgaircom...
  • Page 20: Warranty

    ECOZONE in writing. The Ozone Filtering Unit (shown in the picture on page 18 as #17) is a consumable and is expressly excluded from this warranty.
  • Page 21 LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANT\ GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. Contact information: Ecozone Technologies, Ltd. New York Office Flasharon Industrial Park 400 East 70" St, Suite 2603 P.O.B 5014...