INTRODUCTION
1.
When two ND500II 125 watt radiobeacon
transmitters, an NAX51A computer remote control
unit (CRCU) and an NDDS/T Dual Direct Digital
Synthesizer (DDS) are installed in a main/standby
installation, some mechanical information in the
transmitter's instruction manual must be changed and
the cabinet's electrical information is required. This
document identifies the mechanical differences. It
also provides an electrical parts list and point-to-
point wiring information for the cabinet.
recommended that, where replacement pages are not
provided, affected areas of the transmitter instruction
manual be highlighted using a suitable marker, or
changed using pen and ink, to ensure users of the
manual are aware of the differences.
1.1
MAIN
TRANSMITTER:
transmitter identified as ND500II-113-x21 on its
nameplate must be used as the main transmitter.
This transmitter has an NAF107/02 harmonic filter
assembly,
which
contains
changeover relay and an additional type 'N' coaxial
connector (J3). The changeover relay ensures only
one transmitter is turned on and that the RF output of
the active transmitter is applied to the antenna
system's antenna tuning unit (ATU).
transmitter is enabled as long as its RF output is
satisfactory. See ND500II instruction manual for
details on the NAF107/02 harmonic filter assembly.
1.2
STANDBY TRANSMITTER:
transmitter identified as ND500II-013-x21 on its
nameplate must be used as the standby transmitter.
MECHANICAL DIFFERENCES
2.
There are no drawer slides on the
transmitters, as depicted in figure MD-17.
method of installation will determine how access is
gained for servicing. References to extension and
swivelling of the transmitter in the instruction
manual should be ignored. If it is not possible to
access a specific area of the transmitter when it is
installed, the transmitter must be moved to a suitable
work surface.
(USER SUPPLIED ENCLOSURE/CABINET)
It is
The
a
main/standby
The main
The
The
IS02007 (Page 1)
15 February 2002
OPERATION
3.
Refer to the ND500II technical instruction
manual for transmitter operation, including the
function of the remote inputs and outputs which are
not related to main/standby operation. Refer to the
NAX51 manual for computer remote control unit
(CRCU) operation. Refer to the NAX198 manual
for NDDS/T operation.
NOTE
The 'A' transmitter contains the main/standby RF
routing relay. This relay is connected as a fail-safe
device which is energized when the 'A' transmitter is
operational (on-air) and de-energized when the 'A'
transmitter
is
non-operational
shutdown). When the relay is energized, the RF
output of the 'A' transmitter is routed to the antenna.
When the relay is de-energized, the RF output of the
'B' transmitter will be routed to the antenna.
3.1
SYSTEM OPERATING STATUS: The
system's xmtr on status and shutdown alarm outputs
provide an indication of the system operating status.
3.1.1
If the 'A' or 'B' transmitter is turned on and
producing a satisfactory RF output, the following
will be true, regardless of the system's main/standby
status:
(a)
The system's xmtr on status output at 3TB2-10
(
) of the remote control interface
XMTR ON
assembly will be a ground potential.
(b)
The system's shutdown alarm output at 3TB1-3
(
) of the remote control interface
SHT DN ALM
assembly will be a positive DC voltage.
3.1.2
If neither transmitter is enabled (not
turned on or shut down because of malfunctions),
indicating the system is non-operational and is not
producing an RF output, the following will be true:
(a)
The system's xmtr on status output at 3TB2-10
(
) of the remote control interface
XMTR ON
assembly will be a positive DC voltage.
(b)
The system's shutdown alarm output at 3TB1-3
(
) of the remote control interface
SHT DN ALM
assembly will be a ground potential.
(turned
off/

Advertisement

Table of Contents
loading

Summary of Contents for Nautel ND500II-113-x21

  • Page 1 MAIN TRANSMITTER: When the relay is de-energized, the RF output of the transmitter identified as ND500II-113-x21 on its 'B' transmitter will be routed to the antenna. nameplate must be used as the main transmitter. This transmitter has an NAF107/02 harmonic filter...
  • Page 2: Operation

    MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) MAIN/STANDBY OPERATION: The system's remote audio output at 3TB1-9 Main/standby operation requires the 'A' and 'B' ) of the remote control interface RMT AUD transmitters to be in-circuit and functional. assembly will be provided by the selected main main/standby control circuitry on the remote control transmitter.
  • Page 3: Theory Of Operation

    MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) When the ground potential is removed from The system's changeover alarm output at 3TB1-10 ( ) of the remote control 3TB2-6 or the switch is CHG OV ALM REMOTE TRANSFER interface assembly will be a ground potential, set to...
  • Page 4: Main/Standby Configuration

    MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) ground potential. The B+VDC output at TB1-10 of the transmitter will be the B+ voltage. The sht dn alm output at 3TB1-3 will be a The remote shutdown alarm output at TB2-7 of positive DC voltage.
  • Page 5: Installation Information

    MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) energized when the main transmitter is shut energized (transmitter 'A' is selected as the down and applying a positive DC voltag as the main transmitter but it has failed, a changeover changeover alarm.
  • Page 6 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) If the antenna feed cable is connected: 5.2.2 The transmitter which must be installed as the 'B' (xmtr 2) transmitter has a '0' as the first digit directly to the main transmitter's RF output of the first group of three numbers (ND500-0xx-xxx) connector (A7J2), connect the heavy gauge on its transmitter variation nameplate.
  • Page 7 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) Check the operation of the slave computer Connect the Coax Cable Assembly (158-1170- remote control unit as described in its 01) found in the ‘B’ transmitter’s ancillary kit instruction manual.
  • Page 8 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) Figure 1 External Control/Monitor Interconnecting Wiring IS02007 (Page 8) 15 February 2002...
  • Page 9: Initial Start-Up Procedures

    MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) INITIAL START-UP PROCEDURES CHECK TRANSMITTER 'B': Complete a stand alone functional test of transmitter The initial start-up procedures consist of an 'B' as follows: individual functional test for the computer remote control unit, the digital synthesizer and each transmitter and then a check of main/standby NOTE...
  • Page 10 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) switch on the remote control The system changeover alarm output at 3TB1- RMT XFR interface assembly to 10, of the remote control interface assembly, DISABLE shall switch to a ground potential, indicating 6.6.1 Transmitter 'A' as Main Transmitter: transmitter 'A' has failed and an automatic...
  • Page 11 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) 6.6.2 Transmitter 'B' as Main Transmitter: The system changeover alarm output at 3TB1- Check main/standby operation when transmitter 'B' is 10, of the remote control interface assembly, shall switch to a ground potential, indicating selected as the main transmitter: transmitter 'B' has failed and an automatic Set the...
  • Page 12 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) 6.6.3 Remote Check of Standby Transmitter: Apply a ground potential transfer command to Verify the standby transmitter can be enabled from a 3TB2-6, of the remote control interface remote location, to check its operational status: assembly, from a remote source.
  • Page 13 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) Table 1 Wiring List - Remote Control Interface Assembly (158-7203-02) SOURCE DESTINATION CODE SIZE REMARKS TT1 (Anode) Diode 1N5624 TT3 (Anode) Diode 1N5624 XK1-13 (Anode) XK1-14 Diode 1N4938 XK3-13 (Anode) XK3-14 Diode...
  • Page 14 MAIN/STANDBY 125 WATT RADIOBEACON TRANSMITTERS WITH CRCU and NDDS/T (USER SUPPLIED ENCLOSURE/CABINET) Table 2 - Ref Des Index - Main/Standby 125W Radiobeacon Transmitter System with CRCU NAME OF PART NAUTEL'S JAN/MIL/OEM CODE AND DESCRIPTION PART NO. PART NO. CODE Enclosure (User Supplied) ♦...
  • Page 15 Figure SD-1 Electrical Schematic - Main/Standby 125W Radiobeacon Transmitter System with CRCU/NDDS/T IS02007 (Page SD-1) 15 February 2002...
  • Page 16 Figure SD-2 Electrical Schematic - Remote Control Interface Assembly (P/N 158-7203-02) IS02007 (Page SD-2) 15 February 2002...
  • Page 17 Figure MD-1 Assembly Detail - Remote Control Interface Assembly (P/N 158-7203-02) IS02007 (Page MD-1) 15 February 2002...