Steady-State Air Consumption
3610J: 0.40 normal m
(20 psig) supply pressure
3610JP: 0.64 normal m
(100 psig) supply pressure
3620J: 0.49 normal m
(20 psig) supply pressure
3620JP: 0.93 normal m
bar (100 psig) supply pressure
Operative Temperature Limits
−40 to 82_C (−40 to 180_F)
Hazardous Area Classification for 3610J, 3610JP,
and 3611JP
Complies with the requirements of ATEX Group II
Category 2 Gas and Dust
Electrical Classification for 3620J, 3620JP, and
3621JP
Hazardous Area:
Explosion proof, Dust-Ignition proof,
DIV 2, Intrinsic Safety, Type n
Explosion proof, Dust-Ignition proof,
Non-incendive, Intrinsic Safety, Type n
APPROVED
Intrinsic Safety, Type n, Flameproof
ATEX
(Gas Atmospheres Only)
SAA
Intrinsic Safety, Type n, Flameproof
Refer to Special Instructions for "Safe Use" and
Installation in Hazardous Locations, tables 4, 5, 6,
and 7 and figures 31, 32, 33, 34, and 35 for
additional information.
NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 − Process Instrument Terminology.
1. For direct action, an increasing input signal extends actuator rod. For reverse action, an increasing input signal retracts actuator rod.
3
2. Normal m
/hr—Normal cubic meters per hour (0_C and 1.01325 bar, absolute). Scfh—Standard cubic feet per hour (60_F and 14.7 psia).
3. The pressure and temperature limits in this document, and any applicable code or standard should not be exceeded.
4. Natural gas should contain no more than 20 ppm of H
Table 2. EMC Immunity Performance Criteria for 3620J, 3620JP, 3621JP and 3622
Port
Electrostatic Discharge (ESD)
Radiated EM field
Enclosure
Rated power frequency magnetic field
Burst
Surge
I/O signal/control
Conducted RF
Specification limit = ±1% of span
1. A= No degradation during testing. B= Temporary degradation during testing, but is self-recovering.
4
Table 1. Specifications (Continued)
(2)
3
/hour (15 scfh) at 1.4 bar
3
/hour (24 scfh) at 6.9 bar
3
/hour (18.2 scfh) at 1.4 bar
3
/hour (35.0 scfh) at 6.9
(3)
S.
2
Phenomenon
Basic Standard
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-8
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
Housing Classification for 3620J, 3620JP, and
3621JP
CSA Type 3 Encl., NEMA 3, IP54 per IEC 60529;
Instrument should be mounted with vent on side
or bottom to meet weatherproofing classification
Pressure Connections
1/4 NPT internal
Conduit Connection for 3620J, 3620JP, and
3621JP
1/2 NPT internal (standard), M20 or PG13
adapter (optional)
Rotary Valve Rotation
60, 75, or 90 degrees
Sliding Stem Valve Travel
mm
Inches
11
0.4375
19 to 51
0.75 to 2
29 to 51
1.125 to 2
51 to 102
2 to 4
Approximate Weight
3610J Series: 2.5 kg (5.6 pounds)
3620J Series: 3.6 kg (8.0 pounds)
Declaration of SEP
Fisher Controls International LLC declares this
product to be in compliance with Article 3
paragraph 3 of the Pressure Equipment Directive
(PED) 97 / 23 / EC. It was designed and
manufactured in accordance with Sound
Engineering Practice (SEP) and cannot bear the
CE marking related to PED compliance.
However, the product may bear the CE marking
to indicate compliance with other applicable
European Community Directives.
Test Level
4 kV contact; 8 kV air
80 to 1000 MHz @ 10V/m with 1 kHz AM at 80%
60 A/m at 50 Hz
1 kV
1 kV (line to ground only, each)
150 kHz to 80 MHz at 3 Vrms
Instruction Manual
June 2008
(1)
Performance Criteria
A
A
A
A
B
A