– This information will not be lost from memory due to a power failure. – Should the distance prove unsatisfactory, simply readjust by changing the position of the piece of paper. – Replace the control-box cover. – The recognition range can also be adjusted using the Oras Data Terminal (v. 2. or later).
After-flow Time (6401 & 6402) – Factory-set to 1 second – After-flow time can be adjusted using the Oras Data Terminal (v. 2. or later). Cleaning the Filter (6401 & 6402)(fig. 1) – Shut off the water supply to the faucet.
Page 8
Changing the non-return valve (fig. 1) – Close the water inlet to the faucet. – Remove the connecting hose from the mixing unit. – Pull the non-return valve () out of the mixer unit and changed the new one. – Reassemble the parts. Changing a damaged photocell (6401 &...
Installing a new printed circuit board – Place the new printed circuit board (2) into the control box and screw on the locking screws (2). – Reattach the wires (7) to the solenoid valve connectors (8). – Push the sensor cable back into the connectors (1). –...
Page 10
– Jos etäisyys ei ole tyydyttävä voidaan säätö suorittaa samalla tavalla uudelleen, mutta paperin paikkaa muutetaan. – Asenna ohjauslaatikon kansi paikoilleen. – Tunnistuetäisyyttä voidaan myös muuttaa Oras Data Terminalin avulla (ohjelmaversio 2. tai uudempi). Jälkivirtaaman säätö (6401 & 6402) – Tehdasasetus 1 sek. – Jälkivirtaama säädetään Oras Data Terminalin avulla (ohjelmaversio 2. tai uudempi).
Page 16
ISO 9001:2000 and ISO different purposes enable you 1001:200 are fulfilled. to find the right faucet for every purpose. For the further details please apply to Oras web site at www.oras.com ORAS GROUP Isometsäntie 2, P.O. Box 0 FI-2101 Rauma Finland Tel.