Viking 63299 Owner's Manual & Safety Instructions page 11

12v-2/8/15 amp fully automatic microprocessor controlled battery charger

Advertisement

troubleshooting Error codes
Error code
REVERSE
POLARITY
OVER
HEAT
BATTERY
VOLTAGE
TOO HIGH
24Hr
OVERTIME
CHARGING
BATTERY
FAILURE
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.
record product's Serial number Here:
note: If product has no serial number, record month and year of purchase instead.
note: Internal parts are not user-serviceable and are not available.
Item 63299
possible causes
Clamps connected to wrong
terminals on battery.
The Charger is overheating.
Charger may be connected
to 24  V battery.
1. An appliance is drawing power
from battery being charged.
2. Selected charging rate is
too low for battery rating.
Defective battery, will not
hold full charge.
For technical questions, please call 1-888-866-5797.
Likely Solutions
Correct clamp connections on battery.
Make sure air vents on Charger are
clear. Charger will automatically resume
charging when it has cooled down.
Verify battery being charged is 12  V .
1. Disconnect the appliance and
charge battery again.
2. Select higher charging rate and
continue charging battery.
Have battery checked by a qualified
technician. Replace battery if necessary.