P60
filter coefficient
P61
driver current type
P62
V phase current Zero
point adjusted value
P63
W phase current Zero
point adjusted value
Remarks:
① It is immediately valid after modification;
② Fixed parameters cannot be modified;
③ I shall be valid when restarting it after modification.
Parameters Detailed table:
SN
Parameter
Name
P0
Software
version
P1
Parameter
password
P2
Motor
model
P, S, T
P, S, T
P, S, T
Functional Description
Display different versions
The correct password should be input and confirmed
when parameter is required to modify after power
connection;
Set to be 0 when delivery from factory;
9999 can be input when the password is failure;
11111 is the universal password。
22222 can be input to correct the current zero.
Motor model is entered to directly impact on the
following protection features: over-current, overload, and
over-speed protections.
Specification for motor model
26
Single-channel all-digital AC servo drives QS7 Series
0
0-9
0
0-1
2008-2088
2008-2076
Paramete
r Range
2015-
0-32000