  • Page 1 INSTRUKCJA OBSŁUGI USER MANUAL MANUAL DE USO DIT-500 v1.7 05.03.2020...
  • Page 3 INSTRUKCJA OBSŁUGI PIROMETR BEZKONTAKTOWY TERMOMETR PRACUJĄCY W PODCZERWIENI DIT-500 Wersja 1.7 05.03.2020...
  • Page 4 Do najważniejszych funkcji bezkontaktowego termometru DIT-500 należą:  szybka reakcja na zmiany temperatury,  dokładne, bezkontaktowe pomiary temperatury,  podwójny celownik laserowy,  nowoczesna konstrukcja obudowy,  automatyczna funkcja Data Hold (zatrzymywania wyświetlanych danych pomiarowych),  wybór jednostki ºC/ºF, ...
  • Page 5: Table Of Contents

    6.3 Rejestrator danych ..........16 6.3.1 Zapisywanie danych ........... 16 Przeglądanie danych ..........16 6.3.2 Kasowanie pamięci ............ 17 6.3.3 6.3.4 Funkcja USB .............. 17 7 Wymiana baterii ..........18 8 Czyszczenie i konserwacja ....... 19 9 Magazynowanie ..........19 DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 6: Wstęp

    11 Dane techniczne..........20 12 Akcesoria standardowe ........21 13 Serwis ..............22 1 Wstęp Dziękujemy za zakup pirometru DIT-500. Urządzenie niniejsze umożliwia bezkontaktowe pomiary temperatury w podczerwieni za jednym naciśnięciem przycisku. Wbudowany wskaźnik laserowy podnosi dokładność celu, podczas gdy podświetlany wyświetlacz LCD oraz poręczne przyciski zapewniają...
  • Page 7: Bezpieczeństwo

     naprawy mogą być wykonywane wyłącznie przez autoryzowany serwis. UWAGA ! PROMIENIOWANIE LASEROWE NIE KIEROWAĆ WZROKU W STRONĘ WIĄZKI LASEROWEJ. ------------------------------------------------------------------------- PÓŁPRZEWODNIKOWA DIODA LASEROWA Moc wyjściowa <1mW przy 675 nm LASER KLASY II. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 8: Opis Funkcjonalny

    3. Wejście sondy Typu K 4. Port USB 5. Przycisk PODŚWIETLENIA/LASERA 6. Przycisk W GÓRĘ 7. Przycisk W DÓŁ 8. Przycisk TRYBU (MODE) 9. Przycisk pomiaru temperatury 10. Pokrywa baterii 11. Uchwyt 12. Przycisk otwierający pokrywę baterii DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 9: Wyświetlacz

    12. Jednostka temperatury ºC/ºF 13. Symbol alarmu wartości wysokiej (HAL) i niskiej (LAL) 14. Wskaźnik transmisji danych do komputera 15. Wskaźnik niskiego poziomu baterii 16. Wartość emisyjności, temperatury z sondy K lub temperatury zapisanej w pamięci DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 10: Przyciski

    Przyciski 1. Przycisk włączający i wyłączający laser oraz podświetlenie LCD 2. Przycisk W DÓŁ (dla , HAL, LAL) 3. Przycisk W GÓRĘ (dla , HAL, LAL) Cyklicznie działający przycisk MODE (TRYB) DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 11: Odległość I Rozmiar Plamki

    W urządzeniach wyposażonych w celownik laserowy, laser jest stosowany wyłącznie w celu ukierunkowania pomiaru.  Pole widzenia Należy się upewnić, że cel jest większy niż rozmiar plamki urządzenia. Im mniejszy jest cel, tym bliżej niego winno DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 12 Odczekać aż taśma osiągnie tę samą temperaturę jak materiał pod nią a następnie zmierzyć temperaturę taśmy lub pomalowanej powierzchni. umożliwia kompensację błędu Miernik DIT-500 spowodowanego innym współczynnikiem emisyjności niż 0.95. W tym celu należy wprowadzić poprawną wartość emisyjności dla danej substancji. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 13 0,90 do 0,94 Papier 0,70 do 0,94 Marmur 0,94 Tlenki chromu 0,81 Tynk 0,80 do 0,90 Tlenki miedzi 0,78 Zaprawa mu- 0,89 do 0,91 Tlenki żelaza 0,78 do 0,82 rarska Cegła 0,93 do 0,96 Tekstylia 0,90 DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 14: Wykonywanie Pomiarów

    Wynika to z procesu chłodzenia, który musi zostać przeprowa- dzony dla czujnika podczerwieni. 6 Funkcje specjalne Funkcjonalność  W trakcie pomiarów kolejne naciśnięcie przycisku ④ (MODE) powoduje wyświetlenie wartości maksymalnej, wartości minimalnej, wartości różnicowej, wartości średniej lub numeru komórki pamięci. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 15: Przycisk Tryb (Mode)

    Za każdym razem, gdy zostaje naciśnięty przycisk MODE, na- stępuje przejście do kolejnej pozycji w cyklu trybów. Edycja po- szczególnego parametru sygnalizowana jest miganiem odpowied- niego symbolu na wyświetlaczu. Sekwencja działania pokazana jest na Rys. 1. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 16 MAX, MIN, DIF, AVG, LOG  ustawienie pomiar ciągły WŁ/WYŁ HAL WŁ/WYŁ TRYB regulacja HAL LAL WŁ/WYŁ regulacja LAL wybór Rys. 1. Sekwencja przycisku MODE (TRYB) DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 17: Wyświetlanie Wartości Max, Min, Dif, Avg

    Alarm niskich wartości temperatury (LAL) 6.2.6 Włączyć lub wyłączyć alarm niskich wartości temperatury po- przez naciśnięcie przycisku W GÓRĘ/W DÓŁ. 6.2.7 Ustawienia progu LAL Ustawienia alarmu dla niskich wartości temperatur dokonywane są poprzez naciśnięcie przycisku W GÓRĘ/W DÓŁ. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 18: Rejestrator Danych

    LOG przestanie migać a na górnym polu od- czytowym pojawi się numer komórki pamięci. Na dolnym polu od- czytowym będzie zapisana temperatura dla tej komórki. Celem przejścia do innej komórki pamięci, należy użyć przyci- sków W GÓRĘ/W DÓŁ. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 19: Kasowanie Pamięci

    K do komputera poprzez złącze USB. Aby włączyć lub wyłączyć transmisję danych przez złącze USB należy przez ok. 2s przytrzymać przycisk ①. Włączenie transmisji sygnalizowane jest przez napis USB na wyświetlaczu. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 20: Wymiana Baterii

    Kiedy naładowanie baterii jest niedostateczne, na wyświetlaczu pojawi się symbol „ ” oznaczający, że wymagana jest wymiana na nową baterię 9V. Uwaga: Dokonując pomiarów przy wyświetlonym mnemoniku baterii należy się liczyć z dodatkowymi nieokreślonymi niepewno- ściami pomiaru lub niestabilnym działaniem przyrządu. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 21: Czyszczenie I Konserwacja

    Ustawą o zużytym sprzęcie elektrycznym i elektronicz- nym. Przed przekazaniem sprzętu do punktu zbiórki nie należy sa- modzielnie demontować żadnych części z tego sprzętu. Należy przestrzegać lokalnych przepisów dotyczących wyrzu- cania opakowań, zużytych baterii i akumulatorów. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 22 1℃ lub 1,8℉) 68…752℉ ±(1,5% w.m. + 400…800℃ 2℃ 50:1 752…1472℉ 1000…1600℃ 1℃ lub 3,6℉) 1000…2912℉ 1℉ 800…1600℃ ±2,5% w.m. 1472…2912℉ Temperatura otoczenia w zakresie od 23 do 25℃ (73 do 77℉) „m.w.” oznacza wartość mierzoną wzorcową DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 23 USB,  sonda temperaturowa typu K,  mini statyw,  futerał,  instrukcja obsługi,  karta gwarancyjna,  świadectwo wzorcowania wydawane przez akredytowane labo- ratorium. Aktualne zestawienie akcesoriów znajduje się na stronie interneto- wej producenta. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 24 13 Serwis Prowadzącym serwis gwarancyjny i pogwarancyjny jest: SONEL S.A. ul. Wokulskiego 11 58-100 Świdnica tel. (74) 858 38 00 (Biuro Obsługi Klienta) e-mail: bok@sonel.pl internet: www.sonel.pl Wyprodukowano w Chinach na zlecenie SONEL S.A. DIT-500 – INSTRUKCJA OBSŁUGI...
  • Page 25 14 Usługi laboratoryjne Laboratorium Badawczo - Wzorcujące działające w SONEL S.A. posiada akredytację Polskiego Centrum Akredytacji nr AP 173. Laboratorium oferuje usługi wzorcowania następujących przyrzą- dów związanych z pomiarami wielkości elektrycznych i nieelek- trycznych: ● MIERNIKI DO POMIARÓW WIELKOŚCI ELEKTRYCZNYCH ORAZ PARAMETRÓW SIECI ENERGETYCZNYCH...
  • Page 26 Metody, które mogą być wykorzystane do wyznaczenia odstępów czasu między wzorcowaniami określone są w dokumencie ILAC G24 „Wytyczne dotyczące wyznaczania odstępów czasu mię- dzy wzorcowaniami przyrządów pomiarowych”. Firma SONEL S.A. zaleca dla produkowanych przez siebie przyrządów wykonywanie po- twierdzenia metrologicznego nie rzadziej, niż co 12 miesięcy.
  • Page 27 USER MANUAL NON-CONTACT INFRARED THERMOMETER DIT-500 Version 1.7 05.03.2020...
  • Page 28 Main features of the DIT-500 device are the following:  rapid detection of temperature changes,  precise non-contact measurements,  dual laser lighting,  modern housing design,  automatic Data Hold,  ºC / ºF switch,  emissivity digitally adjustable from 0.10 to 1.00, ...
  • Page 29 Saving data to memory ..........39 6.3.2 Recalling data from memory........39 6.3.3 Memory clear function ..........39 6.3.4 USB function .............. 40 7 Battery replacement .......... 40 8 Cleaning and maintenance ....... 41 9 Storage ..............41 DIT-500 – USER MANUAL...
  • Page 30: Introduction

    13 Manufacturer ............44 14 Laboratory services ........... 45 1 Introduction Thank you for purchase of the IR Thermometer DIT-500. This is capable of non-contact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accura- cy while the backlight LCD and handy push-buttons combine for convenient, ergonomic operation.
  • Page 31: Safety

     If it has been stored for an excessive period of time in inad- equate conditions (e.g. if it is humid).  Before commencing a measurement make sure the correct measurement function has been selected.  Repairs must be realised solely by an authorised service work- shop. DIT-500 – USER MANUAL...
  • Page 32: Functional Description

    ① IR sensor ② LCD Display ③ TYPE K IN ④ USB IN ⑤ LIGHT/LASER BUTTON ⑥ UP BUTTON ⑦ DOWN BUTTON ⑧ MODE BUTTON ⑨ MEASUREMENT TRIGGER ⑩ BATTERY COVER ⑪ HANDLE GRIP ⑫ BATTERY COVER BUTTON DIT-500 – USER MANUAL...
  • Page 33: Lcd Symbols

    C or F symbols ⑬ High alarm (HAL) and low alarm (LAL) symbols ⑭ USB symbol (transmit data to PC) ⑮ Low battery symbol ⑯ Emissivity value, temperature from Type K probe or tempera- ture from memory DIT-500 – USER MANUAL...
  • Page 34: Buttons

    3.3 Buttons ① Laser/Backlight on/off button ② Down button (for , HAL, LAL) ③ Up button (for , HAL, LAL) ④ Cyclic MODE button DIT-500 – USER MANUAL...
  • Page 35: Distance And Spot Size

     Field of View Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When DIT-500 – USER MANUAL...
  • Page 36 Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature of the tape or painted surface. The DIT-500 can compensate additional error of emissivity other than 0.95. In this purpose, enter correct value of meas- ured substance emissivity.
  • Page 37: Measurement Operation

    ① button to turn on/off the laser and turn on/off backlight.  The meter will automatically power down after approximately 7 seconds after the trigger is released (unless the unit is locked on). DIT-500 – USER MANUAL...
  • Page 38: Functional Design

    (HAL) on/off -> HAL adjustment -> low alarm (LAL) on/off -> LAL adjustment -> Each time you press set you advance through the mode cycle. The diagram shows the sequence of functions in the mode cycle. DIT-500 – USER MANUAL...
  • Page 39 MAX, MIN, DIF, AVG, LOG  adjustment LOCK on/off HAL on/off MODE HAL adjustment LAL on/off LAL adjustment Fig. 1. Sequence of MODE button. DIT-500 – USER MANUAL...
  • Page 40: Max, Min, Dif, Avg Display

    Low alarm (LAL) on/off Turn on or off low alarm by pressing UP/DOWN button. 6.2.7 LAL adjustment Please adjust low alarm value by pressing UP/DOWN button. 6.2.8 Pressing UP/DOWN button to change the temperature unit (℃ or ℉). DIT-500 – USER MANUAL...
  • Page 41: Data Logger

    Note: This can only be done when the trigger is pulled. LOG loca- tion “000” cannot be accessed, by using the UP arrow button.  when LOG location “000” shows in the display, press the LASER/BACKLIGHT button. A tones will sound, and the LOG DIT-500 – USER MANUAL...
  • Page 42: Usb Function

    USB function turn on. Then, press the LIGHT/LASER button again until “USB” sign disappears. Thus, the USB function shut off. 7 Battery replacement As battery power is not sufficient, LCD will display “ ”. Re- placement with one new battery type 9V is required. DIT-500 – USER MANUAL...
  • Page 43: Cleaning And Maintenance

    Before the equipment is sent to a collection point, do not dis- mantle any elements. Observe the local regulations concerning disposal of packages, worn-out batteries and accumulators. DIT-500 – USER MANUAL...
  • Page 44 68…752℉ 1℃ or 1,8℉) ±(1,5% m.v. + 400…800℃ 2℃ 50:1 752…1472℉ 1000…1600℃ 1℃ or 3,6℉) 1000…2912℉ 1℉ 800…1600℃ ±2,5% m.v. 1472…2912℉ Operating temperature of 23 to 25℃ (73 to 77℉) “m.v.” means measured value of standard. DIT-500 – USER MANUAL...
  • Page 45  K Type probe,  mini tripod,  carrying case,  user manual,  warranty card,  calibration certificate issued by an accredited laboratory. The current list of accessories can be found on the manufacturer's website. DIT-500 – USER MANUAL...
  • Page 46 58-100 Świdnica Poland Tel: +48 74 858 38 60 Fax: +48 74 858 38 09 E-mail: export@sonel.pl Web page: www.sonel.pl Note: Service repairs must be realized solely by the manufacturer. Made in China for SONEL S.A. DIT-500 – USER MANUAL...
  • Page 47 14 Laboratory services SONEL Testing and Calibration Laboratory has been accredited by the Polish Center for Accreditation (PCA) - certificate no. AP 173. Laboratory offers calibration for the following instruments that are used for measuring electrical and non-electrical parameters. ● METERS FOR MEASUREMENTS OF ELECTRICAL...
  • Page 48 National Metrological Institute. According to ILAC-G24 „Guidelines for determination of calibration intervals of measuring instruments”, SONEL S.A. recommends pe- riodical metrological inspection of the instruments it manufactures no less frequently than once every 12 months.
  • Page 49 MANUAL DE USO PIRÓMETRO TERMÓMETRO SIN CONTACTO EN INFRARROJOS DIT-500 Versión 1.7 05.03.2020...
  • Page 50 DIT-500 – MANUAL DE USO...
  • Page 51 Registro de datos ............62 Revisión de datos............62 6.3.2 6.3.3 Borrado de memoria ..........63 Función de USB ............63 6.3.4 7 Reemplazo de batería ........64 8 Limpieza y mantenimiento ........ 65 9 Almacenamiento ..........65 DIT-500 – MANUAL DE USO...
  • Page 52: Introducción

    11 Datos técnicos ........... 66 12 Accesorios estándar ......... 67 13 Mantenimiento ............ 68 1 Introducción Gracias por comprar el pirómetro DIT-500. Este dispositivo permite medir la temperatura sin contacto en infrarrojos con un solo pulsado de botón. El puntero láser incorporado aumenta la precisión del objetivo, mientras que la pantalla LCD con iluminación...
  • Page 53: Seguridad

    ¡ATENCIÓN! RADIACIÓN LÁSER NO DIRIGIR LOS OJOS HACIA EL HAZ DE LÁSER ------------------------------------------------------------------------- DIODO LÁSER SEMICONDUCTOR Potencia de salida <1mW a 675 nm LÁSER CLASE II DIT-500 – MANUAL DE USO...
  • Page 54: Descripción Funcional

    Entrada de sonda tipo K Puerto USB Botón DE ILUMINACIÓN/LÁSER Botón ARRIBA Botón ABAJO Botón MODO (MODE) Botón de medición de temperatura 10. Tapa de batería 11. Mango 12. Botón que abre la tapa de la batería DIT-500 – MANUAL DE USO...
  • Page 55: Pantalla

    13. Símbolo de alarma del valor alto (HAL) y bajo (LAL) 14. Indicador de transmisión de datos al ordenador 15. Indicador de batería baja 16. Valor de emisividad, temperatura de la sonda K o de la temperatura grabada en la memoria DIT-500 – MANUAL DE USO...
  • Page 56: Botones

    Botones 1. Botón para encender o apagar el láser o la iluminación LCD 2. Botón ABAJO (para , HAL, LAL) 3. Botón ARRIBA (para , HAL, LAL) Botón de funcionamiento cíclico MODO (MODE) DIT-500 – MANUAL DE USO...
  • Page 57: Distancia Y Tamaño Del Punto

    En los dispositivos equipados conel visor de láser, el láser sólo se utiliza para orientar la medición.  Campo de visión Debe asegurarse de que el objetivo es más grande que el tamaño del punto del dispositivo. Cuanto menor sea el objeto, DIT-500 – MANUAL DE USO...
  • Page 58 El medidor DIT-500 permite compensar el error causado por otro factor de emisividad que 0,95. Para ello, se debe introducir el valor correcto de emisividad para la sustancia determinada.
  • Page 59: Realización De Mediciones

    ① para encender/apagar la iluminación de la pantalla.  La alimentación del medidor se apagará automáticamente después de aproximadamente siete segundos de soltar el gatillo (a menos que el dispositivo esté en modo de trabajo continuo). DIT-500 – MANUAL DE USO...
  • Page 60: Funciones Especiales

    El ajuste de la alarma alta (HAL), la alarma baja (LAL) y la emisividad () es posible pulsando el botón MODE hasta que aparezca el código correspondiente en la pantalla. Pulse los botones ARRIBA o ABAJO para establecer los valores deseados. DIT-500 – MANUAL DE USO...
  • Page 61: Botón Modo (Mode)

    La edición de cada parámetro correspondiente se indica mediante un parpadeo de un símbolo en la pantalla. La secuencia de operación se muestra en la Fig. 1. DIT-500 – MANUAL DE USO...
  • Page 62 MAX, MIN, DIF, AVG, LOG  configuración medición continua ON /OFF HAL ON/OFF MODO regulación HAL LAL ON/OFF regulación LAL selección Fig. 1. Secuencia del botón MODO (MODE). DIT-500 – MANUAL DE USO...
  • Page 63: Visualización De Valores Max, Min, Dif, Avg

    6.2.5 La configuración de la alarma de temperaturas altas se realiza pulsando el botón ARRIBA/ABAJO. 6.2.6 Alarma de valores bajos de temperatura (LAL) Activar o desactivar la alarma de baja temperatura pulsando el botón ARRIBA/ABAJO. DIT-500 – MANUAL DE USO...
  • Page 64: Configuración De Límite Lal

    Después, con los botones ARRIBA/ABAJO seleccione el modo LOG (LOG parpadeará en la pantalla) y confirme su selección pulsando brevemente el gatillo. LOG dejará de parpadear y en el campo superior de la pantalla aparecerá el número de la célula de DIT-500 – MANUAL DE USO...
  • Page 65: Borrado De Memoria

    Para activar i desactivar la transmisión de datos a través de USB mantenga pulsado durante aprox. 2 segundos el botón ①. La activación de la transmisión viene señalizada con una inscripción USB mostrada en la pantalla. DIT-500 – MANUAL DE USO...
  • Page 66: Reemplazo De Batería

    ” que indica que es necesario cambiar la pila por una nueva de 9V. Nota: Haciendo mediciones en el mostrado mnemónico de la batería hay que tener en cuenta las incertidumbres adicionales medición especificadas funcionamiento inestable del instrumento. DIT-500 – MANUAL DE USO...
  • Page 67: Limpieza Y Mantenimiento

    Antes de enviar el equipo a un punto de recolección no intente desarmar cualquier parte del equipo. Hay que seguir las normativas locales en cuanto a la eliminación de envases, pilas usadas y baterías. DIT-500 – MANUAL DE USO...
  • Page 68 + 2℃ 50:1 752…1472℉ 1000…1600℃ 1℃ o 3,6℉ ) 1000…2912℉ 1℉ 800…1600℃ ±2,5% w.m. 1472…2912℉ Temperatura del ambiente en el rango del 23 a 25℃ (73 a 77℉) "m.w.” significa el valor medido de referencia. DIT-500 – MANUAL DE USO...
  • Page 69  mini trípode,  funda,  manual de uso,  tarjeta de garantía,  certificado de calibración emitido por laboratorio acreditado. La lista actual de accesorios se puede encontrar en el sitio web del fabricante. DIT-500 – MANUAL DE USO...
  • Page 70 El servicio de garantía y postgarantía lo presta: SONEL S.A. Wokulskiego 11 58-100 Świdnica Polonia tel. +48 74 858 38 60 fax +48 74 858 38 09 E-mail: export@sonel.pl Web page: www.sonel.pl Fabricado en China para SONEL S.A. DIT-500 – MANUAL DE USO...