Page 1
For US product support please call 1-800-494-3395, or visit djoglobal.com. For international product support please contact your MEDEN - INMED Sp. z o.o. local dealer, or your corresponding DJO Global site. 2 WENEDÓW STREET You may also contact us internationally at the below KOSZALIN 75-847...
2. FEATURES OF TRITON 6M TRACTION TABLE 2.1. INTENDED USE 2.2. CE MARK 2.3. SYMBOL DEFINITIONS 2.4. TECHNICAL DATA 3. TRACTION TABLE TRITON 6M DESIGN AND FUNCTIONS 3.1. TABLE COMPONENTS 3.2. EQUIPMENT AND ADDITIONAL ACCESSORIES 3.3. TABLE SET 3.4. TRANSPORT AND STORAGE 4.
DJO office or authorized dealer immediately. 4. Repair of the product must be done by the local DJO office or authorized dealer and registered on the repair list in the warranty card. Failure to do so will void the warranty.
2.2. CE mark TRITON 6M Traction table with accessories is manufactured in accordance with the essential requirements for medical devices (Class I, rule 12) and carry a CE mark, according to the manufacturer's declaration. 2.3. Symbol Definitions CAUTION ! This sign denotes operations which - when performed in a way other than described in this manual – may cause injury to the user or damage to equipment.
2.4. Technical data Table 1 shows the technical characteristics of the TRITON 6M traction table: Technical data TRITON 6M arms, chest and 72 cm (28,3 in) head section mid section 22 cm (8,7 in) pelvic section 26 cm (10,2 in)
The frame of the table is made of welded steel sections coated with powder paint. It includes the following components: Picture 1 - Elements of the TRITON 6M Traction table the table support base, equipped with LED, feet and four retractable ①...
CAUTION ! Use only accessories recommended or provided by the manufacturer. Every TRITON 6M traction table is provided with a breathing slot and reinforced mounting point for the traction belt in its front section. Additionally, the tables may be equipped with the following accessories: - traction unit TRU-TRAC/TRITON (recommended by Meden-Inmed);...
It is recommended to have the table examined by a qualified technician. CAUTION ! TRITON 6M traction table has a limited load capacity! The safe working load should not exceed 200 kg (440 lbs) when lifting and the total load should not exceed 275 kg (606 lbs). CAUTION ! If the patient is placed in the wrong position relative to the moving parts of the bed, there is a risk of injury to the body or table structure.
5. PREPARING THE UNIT FOR USE CAUTION ! When setting or changing the place of use of the TRITON 6M traction table, ensure that there are no objects in the space below the bottom frame of the table. Do not allow access to children or animals.
Before starting work the user should make sure that the patient is in a safe position. The height of the Triton 6M table is adjusted using the hand remote and foot control. To raise the table to the desired height, press on the foot control or the on the remote control.
Picture 6 - Regulation elements of TRITON 6M Traction table In order to adjust the tilt of the TRITON 6M front section, release the gas spring lock by holding down the lever (pic. 6 - position A), set the desired position of the front section, and lock in place releasing the lever.
Allen key (No 5). The traction unit base in the TRITON 6M traction tables has a rotation of ± 90 degrees, as well as a step blockade every ~13 degrees. In order to unlock the unit base stand, unscrew the safety lock (pic.8 - A) - the safety knob cannot be unscrewed fully, set the working degree of the traction unit and...
Upholstered cap mounted - work on the table without the traction belt attached. Upholstered cap removed - work on the table with the traction belt attached. Picture 10 - Location for the traction belt hook 2019-08-30 TRITON 6M - User Manual.doc page 13/23...
AC outlet and protected against accidental damage during relocation. CAUTION ! It is forbidden to move the TRITON 6M Traction table with a patient on the table. CAUTION ! Any manipulation of the position change lever WORK-TRANSPORT should be performed with the table without the patient.
To check it is locked, press any button on the remote or foot control. The TRITON 6M is equipped with an access lock mechanism for the height adjustment function. There are two steps of locking access to the height adjustment function...
Avoid extensive wetting of the surface of the table. Disinfect the upholstery and other surfaces using the mild antibacterial detergent. A list of recommended disinfectants is available in the DJO on request. Never use: - cleaning paste, wax, sprays;...
7.3. Checking the gas springs TRITON 6M Traction tables are equipped with gas springs for easy adjustment of the arms, chest & head and leg section inclination angle. To ensure proper performance of the gas springs check the springs visually for leaks every 3 months.
Exceeded safe working load Reduce the load on the table. interrupts operation If the fault persists, stop using the table, unplug the power cord, remove the lock and contact the supplier or the manufacturer. 2019-08-30 TRITON 6M - User Manual.doc page 18/23...
9. EMC guidance and manufacturer’s declaration Essential Performance - there are no essential performance characteristics according to the risk assessment of the equipment* Traction table TRITON 6M. Guidance and manufacturer’s declaration – electromagnetic emissions The equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the equipment should assure that it is used in such an environment.
Page 20
These guidelines may not apply in all equipment situations. Electromagnetic propagation is IEC 61000-4-3 affected by absorption and reflection from Professional Professional structures, objects and people. healthcare facility healthcare facility environment environment 2019-08-30 TRITON 6M - User Manual.doc page 20/23...
Page 21
The carrier shall be modulated using a 50 % duty cycle square wave signal. As an alternative to FM modulation, 50 % pulse modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case. 2019-08-30 TRITON 6M - User Manual.doc page 21/23...
9. The warranty does not cover consumable materials and components (e.g. gaskets, cables, etc.). 10. DJO Global is not responsible for the safety of the user or the patient during the operation of the installed equipment in case of failure to comply with the supplied installation and operating instructions.
Need help?
Do you have a question about the TRITON 6M and is the answer not in the manual?
Questions and answers