  • Page 1 subzero.com 800.222.7820 Service Manual Technical Data...
  • Page 2 Technical Data & Tech Tips Model 235 Model 235 SERVICING INFORMATION SERVICEABLE ELECTRICAL COMPONENTS SERVICEABLE PARTS Part No. Wattage Resistance COMPRESSOR 2176659 Run Winding 1 - 5Ω Start Winding 3 - 11Ω RELAY 2183410 OVERLOAD 2183404 WATER PUMP 2185748 26 - 30 15.95Ω...
  • Page 3 Technical Data & Tech Tips Model 235 Model 235 CYCLE CHARTS ON CYCLE OPERATION POWER ON START UP ONLY SECONDS ICE MAKING HARVEST ICE BIN FULL *ICE BIN NOT FULL >6.5 F <52 F <35 F >41 F WATER VALVE...
  • Page 4 Technical Data & Tech Tips Model 235 Model 235 PERFORMANCE AND PRODUCTION TABLES PERFORMANCE DATA Suction Pressure Head Pressure at End of at End of Temperature Freeze Cycle Freeze Cycle Cycle Time Ambient 70°F (21°C) Water 60°F (16°C) 1 - 4 psi 65 - 80 psi 18 - 22 Min.
  • Page 5 Technical Data & Tech Tips Model 235 Model 235 CIRCUIT BOARD JUMPERS (To Adjust Ice Thickness) NOTE: This information can also be found on the control board. CODE CODE CODE NORMAL THICK THIN Cut-Out Values Cut-Out Values Cut-Out Values 6.5 F – .3 4.5F –...
  • Page 6 Technical Data & Tech Tips Model 235 Model 235 Optional Drain Pump The optional drain pump consists of a motor, a pump that is magnetically coupled to the motor, a water reservoir with sensing devices, an electronic control board that controls the water level in the reservoir using the sensing probes.
  • Page 7 Technical Data & Tech Tips Model 235 Model 235 Install the drain pump. Carefully slide in, aligning the tab on the pump base to the rectangular slot in the unit base. (Fig. 2) Fig. 2 Pump Mounting Attach the drain tube from the bin to the pump inlet. Install the vent tube and drain tube to the household drain before securing the pump to the unit base.