  • Page 1 User Guide SentryPlus Alert ™ Cellular Gateway...
  • Page 2: Table Of Contents

    Keep this Manual for future reference. This User Guide provides information about the different LED lights, buttons, and connectors inside the SentryPlus Alert Cellular Gateway, as well as troubleshooting suggestions if needed . For more information about the Cellular Gateway, see the Installation, Operation, and Maintenance Manual .
  • Page 3: Startup Sequence

    The device is turned on. If the device is plugged in, but this The +12Vdc and GND wiring could be LED is not on, the device is not reversed. See POWER LED is Off on receiving power. page 8. UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 4: Cellular

    “flood notification” via text, it is more than a slight drip. email and/or a phone call. Note: This will only turn on if water discharge is detected. There is no discharge occurring. UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 5: Buttons

    Note: You can also perform a full reset by unplugging the Cellular Gateway for 10 seconds and then plugging it back in . TEST This is for internal use only; do not press this button . PROG This is for factory use only; do not press this button . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 6: Terminals

    Terminals The FLOOD terminals connect the Cellular Gateway to the Junction box . The GND/+12Vdc terminals connect the Cellular Gateway to a power outlet . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 7: Troubleshooting

    This section provides troubleshooting solutions to the most common issues if your Cellular Gateway is not working correctly . If you are unable to resolve your issue, contact your local Watts representative to order a replacement device . Poor or No Cellular Reception Poor or no cellular reception will cause notifications to not work .
  • Page 8: Power Led Is Off

    If the Cellular Gateway is plugged in and the POWER LED is off, the +12Vdc & GND wiring inside the Cellular Gateway might have been accidentally swapped . Solution Use the instructions on the next several pages to swap the +12Vdc and GND wiring inside the Cellular Gateway . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 9 2 . Using a #2 Phillips head screwdriver, remove the four screws that secure the cover of the Cellular Gateway; set them aside . 3 . Carefully remove the cover and place it aside . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 10 . 6 . Carefully insert the reversed wires into the terminals; you might need to hold the wires in place and tighten the screws at the same time . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 11 8 . Place the cover back on the Cellular Gateway, ensuring that the rubber seal remains in place, paying special attention to each corner near the screw holes . 9 . Using a #2 Phillips head screwdriver, reinstall the four screws that secure the cover of the Cellular Gateway . UserGuide-SentryPlusAlert 2007 © 2020 Watts...
  • Page 12: No Connection To The Cloud

    Cellular Gateway or to the cellular service provider . Limited Warranty: Watts (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.