Watts SentryPlus Alert Installation, Operation And Maintenance Manual
Watts SentryPlus Alert Installation, Operation And Maintenance Manual

Watts SentryPlus Alert Installation, Operation And Maintenance Manual

Universal upgrade kit
Hide thumbs Also See for SentryPlus Alert:

Advertisement

Quick Links

Installation, Operation, and
Maintenance Manual
SentryPlus™ Alert
Universal Upgrade Kit

Table of Contents

Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Understanding Safety Information. . . . . . . . . . . . . . . . . . . . 2
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
List of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Installing the Cellular Gateway . . . . . . . . . . . . . . . . . . . . 6
4. Setting Up the Cellular Gateway . . . . . . . . . . . . . . . . . . . 6
5. Registering SentryPlus Alert . . . . . . . . . . . . . . . . . . . . . . 7
Start-up Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Startup Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
NOTICE
Use of the SentryPlus Alert
TM
the need to comply with all required instructions, codes,
and regulations related to the installation, operation, and
maintenance of an RPZ backflow preventor, including the
need to provide proper drainage in the event of a discharge.
Watts is not responsible for the failure of alerts due to
connectivity or power issues.
IOM-UpGradeKit-SentryPlusAlert2
technology does not replace

Advertisement

Table of Contents
loading

Summary of Contents for Watts SentryPlus Alert

  • Page 1: Table Of Contents

    5. Registering SentryPlus Alert ..... . 7 maintenance of an RPZ backflow preventor, including the Start-up Instructions .
  • Page 2: Important Safety Information

    • Wirelessly issues multi-channel alerts (call, text, email) • Can be installed without taking equipment offline • The SentryPlus Alert Technology Universal Upgrade Kit sup- • Learn how to properly and safely use the equipment BEFORE installing, setting up, using, or servicing.
  • Page 3: Installation And Operation

    MUST NOT BE less than ¼" from the pipe wall. Hand tighten the white plastic nuts on the probes to make it water tight. CAUTION Ensure Flood Sensor probes do not contact pipe bottom or sides. IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 4: Installing And Wiring/Retrofitting The Control Box

    10 seconds before the system stabilizes, you can set the time delay to 15 seconds. IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 5 The pressure gauge returns to For New and Existing LFF113RFP Installations zero when the Main Valve is fully open. NOTE: Manual Reset Ball Valve must be closed for normal oper- ation. 3, 4 7, 8 5, 6 IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 6: Installing The Cellular Gateway

    Syncta app by pressing the TEST button. 6. Reset Button – You can reset the Cellular Gateway and restart the start-up sequence by pressing the RESET button . This will cause all on-going operations to cease. IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 7: Registering Sentryplus Alert

    Installation and Operation 5. Registering SentryPlus Alert Using a smart phone or tablet, Follow the prompts to create scan the QR code on the side a Syncta account, or if you are on the Cellular Gateway, or go an existing Syncta user, log in to https://connected.syncta.
  • Page 8: Overview

    Keep this Manual for future reference. Cellular Gateway This User Guide provides information about the different LED lights, buttons, and connectors inside the SentryPlus Alert Cellular Gateway, as well as troubleshooting suggestions if need- For more information about the Cellular Gateway, see the Cellular Installation, Operation, and Maintenance Manual.
  • Page 9: Leds

    Watts Cloud. Blinking There is not a connection to See No Connection to the Cloud on the Watts Cloud. Trying to establish page 9. connection. Flood The FLOOD LED only turns on when excessive relief valve discharge from your backflow assembly is detected.
  • Page 10: Buttons

    Wired to Control Box Terminals Terminals wire to Control Box (PWR, GND, MOD+, MOD-). Terminals labeled INPUT 1 & INPUT 2 are reserved for future use. Power Outlet Ground MOD+ MOD- IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 11: Troubleshooting Guide

    This section provides troubleshooting solutions to the most common issues if your Cellular Gateway is not working correctly. The location has poor cellular reception. If you are unable to resolve your issue, contact your local Watts representative to order a replacement device. Solution 2...
  • Page 12 No Connection to the Cloud Cellular reception might not be supported at your site. If the IoT LED is blinking, there is no connection to the Watts Cloud. If the device is not working, review the possible cause and solution below.
  • Page 13: Warranty

    Notes IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 14 Notes IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 15 IOM-UpGradeKit-SentryPlusAlert2 2013 EDP# 2916013 © 2020 Watts...
  • Page 16 Limited Warranty: Watts (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.

Table of Contents