CTC Union FRM220 Series User Manual
CTC Union FRM220 Series User Manual

CTC Union FRM220 Series User Manual

Chassis qig
Hide thumbs Also See for FRM220 Series:
Table of Contents

Advertisement

cover

FRM220 Chassis QIG
sales@ctcu.com

Advertisement

Table of Contents
loading

Summary of Contents for CTC Union FRM220 Series

  • Page 1: Cover

    cover FRM220 Chassis QIG sales@ctcu.com...
  • Page 2 T +886-2-26591021 F +886-2-26590237 E sales@ctcu.com H www.ctcu.com To download this QIG, please visit https://www.ctcu.com/en/download.html 2020 CTC Union Technologies Co., LTD. All trademarks are the property of their respective owners. Technical information in this document is subject to change without notice.
  • Page 4: Table Of Contents

    Table of Contents cover ............................1 Introduction ..........................6 FRM220-CH01 Single Slot Stand-alone Chassis ..............7 ..............................7 NSTALLATION .............................. 7 OUNTING FRM220-CH01/xx Single Slot Stand-alone Chassis with Built-in Power......... 8 ..............................8 NSTALLATION ............................8 OWER ONNECTION .............................. 9 OUNTING FRM220-CH01M/xx Single Slot Chassis w/ Built-in Power and Console ......
  • Page 5 FRM220 Chassis Quick Installation Guide ............................ 29 ECHANICAL SSEMBLY ............................. 29 ACK MOUNTING ....................30 OWER ODULES EMOVAL EPLACEMENT ..........................30 LECTRICAL NSTALLATION ............................30 LARM NSTALLATION NMC C ..........................31 NSTALLATION ........................... 31 NSTALLATION FRM220-CH20 Twenty Slot 19" 2RU Managed Chassis ............32 ..............................
  • Page 6: Introduction

    FRM220 Chassis Quick Installation Guide Introduction There are many chassis options for FRM220 line cards. Not all chassis options apply to every line card model. Chassis range from the simplest CH01 standalone chassis which provides only physical protection for a one slot line card and includes a 12V@1A (12watt) switching power adapter (wall wart) to a 20 slot, 2U rack chassis with dual, swappable fans and AC or DC power modules.
  • Page 7: Frm220-Ch01 Single Slot Stand-Alone Chassis

    FRM220 Chassis Quick Installation Guide FRM220-CH01 Single Slot Stand-alone Chassis The FRM220-CH01 is designed for tabletop or bench installation. A card slides into the chassis for a complete, assembled, stand-alone unit. AC power is supplied to FRM220-CH01 through an external switching AC adapter.
  • Page 8: Frm220-Ch01/Xx Single Slot Stand-Alone Chassis With Built-In Power

    FRM220 Chassis Quick Installation Guide FRM220-CH01/xx Single Slot Stand-alone Chassis with Built-in Power The FRM220-CH01/xx is designed for tabletop or bench installation. A card slides into the chassis for a complete, assembled, stand-alone unit. This chassis features single or dual built-in power supplies.
  • Page 9: Wall Mounting

    FRM220 Chassis Quick Installation Guide Wall Mounting FRM220-CH01/xx standalone chassis has the option of adding wall mount capability. Two wall mount kits are required for installing a single standalone chassis on the wall. Each wall mount kit provides one wall mounting brackets and the screws to attach the bracket to the CH01/xx chassis. Screws to attach to a wall are not included.
  • Page 10: Frm220-Ch01M/Xx Single Slot Chassis W/ Built-In Power And Console

    FRM220 Chassis Quick Installation Guide FRM220-CH01M/xx Single Slot Chassis w/ Built-in Power and Console The FRM220-CH01M/xx is designed for tabletop or bench installation. A card slides into the chassis for a complete, assembled, stand-alone unit. This chassis features single or dual built-in power supplies.
  • Page 11: Power Connection

    FRM220 Chassis Quick Installation Guide Power Connection The graphic below shows the power connections for the CH01M-AD, with one DC and one AC power supply. When two supplies are connected, they are redundant, and the installed card device will continue operation if only one supply is active. The DC input utilizes a screw terminal block.
  • Page 12: Frm220-Ch02M-Xx Two Slot Standalone Chassis With Console Port

    FRM220 Chassis Quick Installation Guide FRM220-CH02M-xx Two Slot Standalone Chassis with Console Port Introduction The FRM220 chassis product line includes various metal chassis sizes, which can hold from one to twenty FRM220 slide-in modules. The FRM220-CH02M & FRM220-CH02M-HP are a two-slot chassis with built-in cooling fans and DB9 console port for local management, which can be installed with either one or two single width blade cards or one double width blade card.
  • Page 13: Panels

    FRM220 Chassis Quick Installation Guide Panels Console Port Slot 1 Slot 2 Power LED Console Port Indicators Select Switch Figure. Front Panel DC + DC AC + DC AC + AC One DC One AC Power Power Power Power Power Type Type Type...
  • Page 14: Installationi

    FRM220 Chassis Quick Installation Guide Installation I The FRM220-CH02M & FRM220-CH02M-HP, a two blade chassis, can be installed with one double width blade line card into the chassis. The line cards include Imux16 E1Inverse Multiplexer or FOM04 (GFOM04) 4ch E1/T1 Fiber Optical Multiplexer. The FRM220-CH02M & FRM220-CH02M-HP also support DB9 console port for standalone local management.
  • Page 15: Rack Mounting Optioni

    FRM220 Chassis Quick Installation Guide Rack Mounting Option I FRM220-CH02M & FRM220-CH02M-HP standalone chassis have the option of adding standard EIA 19" rack mount capability. The rack mount ear provides for mounting a single standalone chassis in a rack. Each rack mount ear kit provides all the necessary hardware for a complete installation. Figure.
  • Page 16: Frm220-Ch02/Smt Two Slot Standalone Chassis

    NMC card. The available power supplies are built-in AC, DC, 2 AC, 2 DC or AC+DC dual power. All types of single slot FRM220 series cards can be installed into FRM220-CH02/SMT two-slot chassis such as 10G, 2.7G 3R Transponder, 1E1/5E1/8E1 to Ethernet E1 Inverse Multiplexer, Ethernet over Fiber, E1/T1, 35/X21/RS530 fiber modem, POTS over fiber, and RS485/422/232 fiber converter.
  • Page 17: Panels

    FRM220 Chassis Quick Installation Guide Panels Slot 1 Slot 2 Power & FAN LED Indicators Figure. Front Panel Note: For Telnet, Web, Console and SNMP management, NMC card must be inserted in Slot 2. One AC One DC AC + AC DC + DC AC + DC Power...
  • Page 18: Power & Cooling Fan Failure Detection Function

    FRM220 CH20 rack. It can be installed with one single width blade line card into the chassis. All types of FRM220 series one module line card can be installed in FRM220- CH02/SMT chassis, including 10G 3R Transponder, 2.7G 3R Transponder, E1/5E1/8E1 Inverse multiplexer, Ethernet over fiber, E1/T1, 35/X21/RS530 fiber modem, POTS over fiber, and RS485/422/232 fiber converter.
  • Page 19: Frm220-Ch02/Nmc

    FRM220 Chassis Quick Installation Guide FRM220-CH02/NMC Description The FRM220 chassis product line includes various metal chassis sizes, which can hold from one to twenty FRM220 slide-in modules. The FRM220-CH02/NMC is a two slot chassis, which can be SNMP managed when installing one FRM220-NMC Network Management Controller card into the chassis for Web, Telnet, Console and SNMP management.
  • Page 20: Panels

    FRM220 Chassis Quick Installation Guide Panels Slot 1 Slot 2 Power LED Indicators Figure. Front Panel Note: For Telnet, Web, Console and SNMP management, NMC card must be inserted in Slot 2. One AC One DC AC + AC DC + DC AC + DC Power Power...
  • Page 21: Rack Mounting Optioni

    FRM220 Chassis Quick Installation Guide Rack Mounting Option I FRM220-CH02/NMC standalone chassis have the option of adding standard EIA 19" rack mount capability. The rack mount ear provides for mounting a single standalone chassis in a rack. Each rack mount ear kit provides all the necessary hardware for a complete installation. Figure.
  • Page 22: Frm220-Ch04A Four Slot Stand-Alone Chassis

    SNMP Card is installed in the far left hand, upper slot, for local and remote management purposes. Each FRM220 Card is an independent media converter. When linked to a compatible FRM220 Series stand-alone or "I" series FMC (Fiber Media Converter) stand-alone converter, complete in-band management is supported.
  • Page 23: Chassis Physical Dimensions

    FRM220 Chassis Quick Installation Guide Chassis Physical Dimensions Figure. Chassis Dimensions, in millimeters Chassis Specifications Environment Operating Temperature 0~60C Storage Temperature -10~70C Humidity 5~95% non condensing Power Module Specifications AC Power Module Input: Universal, 100~240 ±10% VAC; Frequency: 50/60 Hz ±10% Output: 65W Connector: C14 (IEC 60320-1) DC Power Module...
  • Page 24: Installation

    FRM220 Chassis Quick Installation Guide Installation The Installation will cover the physical installation of the FRM220-CH04A, Rack Mount In-Band Managed Series Fiber Converter Platform Chassis, the electrical connections, interface connections and cabling requirements. A brief overview of the functional components such as main unit and management options will also be outlined in this section.
  • Page 25: Nmc (Snmp)

    1 may then be used for a non-managed media converter line card. Line Card Installation The Line Cards for the FRM220 Series are Fiber Media Converter Cards which slide into CH04A chassis, and interface with the "main board". The media converter cards are designed to be "hot" swappable, meaning CH04A chassis need not be powered off in order to remove or replace a card.
  • Page 26: Frm220-Ch08 Eight Slot 19" 1Ru Managed Chassis

    An SNMP Card is installed in the far left hand, upper slot, for local and remote management purposes. Each FRM220 Card is an independent media converter. When linked to a compatible FRM220 Series stand-alone or "I" series FMC (Fiber Media Converter) stand-alone converter, complete in-band management is supported.
  • Page 27: Led Indicators And Alarm Relay

    FRM220 Chassis Quick Installation Guide LED Indicators and Alarm Relay Color Indication PWR 1 Green When On, indicates good power from module #1 PWR 2 Green When On, indicates good power from module #2 FAN a Green When On, left fan of power module is OK FAN b Green When On, right fan of power module is OK...
  • Page 28: Chassis Specifications

    FRM220 Chassis Quick Installation Guide Chassis Specifications Environment Temperature -10 - 50C Ambient (14-122F) Humidity 5-95% non condensing Alarm relay contact ratings 125VAC 110VDC 0.6A 30VDC Power Module Specifications AC Power Module Input : Universal, 100 ~ 240 ±10% VAC; Frequency : 50/60 Hz ±10% Output : DC 12V, 200W maximum rating Connector : C14 (IEC 60320-1) DC Power Module (two types, DC48 and DC24...
  • Page 29: Line Card Options

    FRM220 Chassis Quick Installation Guide Line card options The FRM220 is capable of supporting a variety of in-band managed or non-in-band managed line card types which may be mixed and matched in any slot of the rack. See below for a brief of the line cards at the time of this printing.
  • Page 30: Power/Fan Modules Removal/Replacement

    FRM220 Chassis Quick Installation Guide Power/Fan Modules Removal/Replacement The Power Supply Modules in CH08 are available in three versions, one AC and two DC types. The universal AC version supports input voltages of 100 to 240 (±10% @ ambient temperature) volts at frequencies of 47 to 63 Hertz.
  • Page 31: Nmc Card Installation

    1 may then be used for a non-managed media converter line card. Line Card Installation The Line Cards for the FRM220 Series are Fiber Media Converter Cards which slide into CH08 chassis, and interface with the back panel "main board". The back panel provides a connection to the converter cards for power and serial control (via NMC).
  • Page 32: Frm220-Ch20 Twenty Slot 19" 2Ru Managed Chassis

    The typical configuration is with one NMC (Network Management Controller) card in slot number 1 and in-band manageable line cards in any other slot numbered 2 through 20. Console Port (DB9F RS-232 Async) FRM220 Series In-Band Managed 115,200, 8, N, 1-DCE Media Converter Cards 10/100Base-TX Ethernet...
  • Page 33: Chassis Rear Description

    FRM220 Chassis Quick Installation Guide Chassis Rear Description The rear panel holds the chassis interface, the hot-swappable cooling fan modules, and the hot- swappable power modules. The pluggable modules do not require any tools for removal and replacement. Alarm 1&2 Relay Chassis Cascade Cooling Fan 1 IEC AC Mains Input...
  • Page 34: Chassis Specifications

    FRM220 Chassis Quick Installation Guide Chassis Specifications Environment Temperature -10 - 50C Ambient (14-122F) Humidity 5-95% non condensing Alarm relay contact ratings 125VAC 110VDC 0.6A 30VDC Power Module Specifications AC Power Module Input : Universal, 100 ~ 240 +6%, -10% VAC; Frequency : 50/60 Hz Output : DC 12V, 200W maximum rating Connector : C14 (IEC 60320-1) DC Power Module...
  • Page 35: Line Card Options

    FRM220 Chassis Quick Installation Guide Line card options The FRM220 is capable of supporting a variety of in-band managed or non-managed line card types which may be mixed and matched in any slot of the rack. See below for a brief of the linecards at the time of this printing.
  • Page 36: Fan Units Removal/Replacement

    FRM220 Chassis Quick Installation Guide Fan Units Removal/Replacement Figure. Removal/Replacement of FRM220 Fan Units Electrical Installation With an AC power module, AC power is supplied to the FRM220 through a standard IEC C14 3- prong receptacle, located on the rear of the module. Any national power cord with IEC C13 line plug may be used to connect AC power to the power module.
  • Page 37: Alarm Installation

    FRM220 Chassis Quick Installation Guide Alarm Installation The alarm relay provides one set of Power Failure contacts (normally open) and another set of FAN Failure contacts (normally open) contacts for monitoring the power and fans condition of the FRM220. The alarm contacts may also be programmed through the management interface to react to different fault conditions.
  • Page 38: Chassis Cascade

    FRM220 Chassis Quick Installation Guide Chassis Cascade The FRM220 chassis may be cascaded in such a manner that only one single IP address is required to manage up to 10 chassis in a single location. The connection diagram is shown below. Each chassis is assigned a unique ID starting at zero for the master chassis and incrementing for each cascaded chassis, up to an ID of nine.
  • Page 39: Power Modules Removal/Replacement

    FRM220 Chassis Quick Installation Guide Power Modules Removal/Replacement The Power Supply Modules in the FRM220 are available in two versions, one AC and one DC type. The universal AC version supports input voltages of 100 to 240 (+6%, -10% @ ambient temperature) volts at frequencies of 50/60 Hertz.
  • Page 40: Line Card Installation

    FRM220 Chassis Quick Installation Guide Line Card Installation The Line Cards for the FRM220 are Fiber Media Converter Cards which slide into the FRM220 chassis, and interface with the pack panel "main board". The back panel provides a connection to the converter cards for power and serial control.
  • Page 41: Frm220 Management Quick Start

    The management methods for the FRM220 include textual based serial console, IP based textual console (Telnet), web based GUI management through web browser, SNMP management through proprietary MIB and via CTC Union's Element Management System (EMS). Console Terminal The NMC card has a DB9F RS-232 serial console port for local management purposes. The console provides a menu driven display, with simple keyboard item selections and the ability to control all aspects of management in the FRM220.
  • Page 42: Tcp/Ip Setup

    TCP/IP Setup From the main menu, use the 'L' key to enter the 'SNMP System Configuration Setup' menu. An example menu is displayed below. **************************************** *** CTC UNION TECHNOLOGIES CO., LTD. *** *** FRM220 NMC VER. 5.35 *** **************************************** << SNMP System Configuration Setup of Chassis 0 >>...
  • Page 43: Telnet Terminal

    FRM220 Chassis Quick Installation Guide Telnet Terminal Use either a Windows® command window or Telnet client application and connect to the FRM220 NMC using the assigned management IP address. The following is an example of a Telnet screen. It is exactly the same as a local serial console screen, only it can be accessed remotely.

Table of Contents