Electrical Connections

Any electrical work required to install this hob should be carried out by a
qualified electrician or competent person, in accordance with the current
regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these safety measures not be observed.
This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.
Before switching on, make sure the electricity supply voltage is the same as that indicated
on the hob rating plate. The rating plate is located on the bottom of the hob. A copy is
attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord incorporating a 3 amp plug fitted.
In the event of having to change the fuse, a 3 amp ASTA approved (BS 1362) fuse must be
used.
Should the plug need to be replaced for any reason, the wires in the mains lead are
coloured in accordance with the following code:
Green and Yellow
Blue
Brown
1) Connect the green and yellow (earth)
wire to the terminal in the plug which is
marked with the letter 'E' or the earth
symbol
yellow.
2) Connect the blue (neutral) wire to the
terminal in the plug which is marked
with the letter 'N' or coloured black.
3) Connect the brown (live) wire to the
terminal in the plug which is marked
with the letter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord
clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed of safely.
The replacement of electric cable must be carried out exclusively by the
service force centre or by personnel with similar competencies, in
accordance with the current regulations.
- Earth
- Neutral
- Live
or coloured green and
FO 0390
21