Installing a 2 (RU) Chassis in a Four-Post Rack
Step 2
Install the chassis into the rack.
a) Use two M4 screws to attach the brackets to the rack.
1
Front-mounting position
Installing a 2 (RU) Chassis in a Four-Post Rack
Before you install the chassis, be sure that the rack is fully secured to the data center floor.
Installing the Switch using the NXK-ACC-RMK-2RU Rack-mount Kit
To install the switch, you must attach mounting brackets to the rack, install slider rails on the rear of the rack,
slide the switch onto the slider rails, install the retainer brackets, and secure the switch to the rack with the
retainer clips. Typically, the front of the rack is the side easiest to access for maintenance.
Note
You must supply the eight 10-32 or 12-24 screws required to mount the slider rails and switch to the rack.
Before you begin
• You have inspected the switch shipment to ensure that you have everything ordered.
• Make sure that the switch rack-mount kit includes the following parts:
Cisco Nexus 3400 Hardware Installation Guide
22
• Rack-mount brackets (2)
• Rack-mount retainer brackets (2)
2
M4 screws (2 each side)
Installing the Chassis