ENFORCER Multi-Function Timer/Counter
Sample Applications (Continued):
5. Use the "Up" or "Down" buttons while viewing the display to set the relay output delay duration
00:00 to 99:99 (for 0~9,999 seconds) after the trigger input and press "Enter" to confirm.
6. The buzzer will sound 3 times and the display will flash through the settings in order (00:04 for
Mode 4, relay output type, time unit, relay output duration, delay duration) and automatically
exit the programming mode returning to display the mode chosen (00:04).
Mode 5: Timed Pulse Relay Output
Mode 5 is similar to "Mode 4" except that the trigger input will produce a timed pulse relay output
(alternating "ON" for 0.5 seconds and "OFF" for 0.5 seconds repeatedly) and there is no delay.
This mode can be set to trigger the relay for a set duration starting from when the input trigger
signal is received or when the trigger input is released, or to toggle a relay on or off. The process
can also be interrupted using a manual reset button (see Fig. 4, pg. 5 for sample wiring diagram).
1. After entering programming mode, use the "Up" or "Down" buttons to set the display to 00:05
to choose "Mode 5" and press "Enter" to confirm.
2. For the remaining programming, continue with steps 2 through 4 of the Mode 4: Timed Relay
Output above.
3. After completing step 4, the buzzer will sound 3 times and the display will flash through the
settings in order (00:05 for Mode 5, relay output type, time unit, relay output duration) and
automatically exit the programming mode returning to display the mode chosen (00:05).
Mode 6: Counter (Count up / Countdown)
The counter mode tracks the number of input
triggers. It can count up from 0 (to a maximum of
9,999 times), showing the current progress on
the display (Note that there is no relay output or
LED/buzzer notification for count up). Or, it can
trigger the output relay/notification LED and/or
buzzer for one second (or an external
notification device) after a set number of trigger
inputs, showing the countdown on the display.
After either count is complete, counting will stop
until manually reset using an external reset
button. A manual reset button can also be used
to reset the count at any time (see Fig. 5 for
sample wiring diagram).
1. After entering programming mode, use the
"Up" or "Down" buttons to set the display
to 00:06 to choose "Mode 6" and press
"Enter" to confirm.
6
Fig. 5 – Modes 6 and 7
N.C.
Relay output
COM
N.O.
Reset input (N.O.
Power input
+
Trigger input
(N.O.+ or N.C.–)
Trigger to
be timed or
counted
(N.O.+)
+
12~24VDC
Power
Supply
*Notification (internal LED/Buzzer or external) only
for countdown counter/timer.
SECO-LARM U.S.A., Inc.
)
+
External
notification
(optional)*
Reset
button
(optional,
N.O.–)