• THC Sensitivity: This is sensitivity reflected by THC (lifter) motor. The larger the value the
more sensitive the system will be to Arc Voltage variation. When the value is set too high,
the torch will become unstable and bounce while moving. The normal range is set as 30-
50%, the full range is 0.00-100.00. Unit: %.
• Arc Set Step Value: From the cutting main screen, Increase or decrease the Set Arc Voltage
value with each press of either F7 or F6. The range of value is 0.10-10.00. Unit: V.
• Fast IHS Time: The lifter motor runs time in full speed when HIS (initial height sensing). Then
the lifter motor runs the half speed until the torch contact the steel plate. Unit: s. Note: Fast
IHS Time cannot be more than Position Check Time. Fast IHS Time range of the value is
5.00-100.00. Unit: V. Default 6.
• Flame Updown Speed: Not used.
• Plasma Updown Speed: Speed at which the torch lifts and lowers when reacting to a torch
height correction command. The normal range is set as 100.00%, the full range is 0.00-
100.00. Unit: %.

System Parameters

The system parameters are related with the precision of transmission shaft of the machine.
Horizontal Axis Pulse
Vertical Axis Pulse
Max cutting speed
Max G00 speed
Max Manual speed
Small arc limit
Speed below Radius
Flame adjust time
Plasma adjust time
Emergency stop time
Start speed
Max +X
Max +Y
Min -X
Min -Y
F1
F2
Common
Flame
263.106
263.158
8500.000
8500.000
8500.000
500.000
10.00
0.40
0.30
0.08
250.000
100000.000
100000.000
-100000.000
-100000.000
F3
F4
Plasma
Marker
36
36
pulse/mm
pulse/mm
mm/min
mm/min
mm/min
mm/min
mm
s
s
s
mm
mm
mm
mm
mm
F5
F6
System
Import
F7
F8
Export
Save

Hide quick links: