To Apply Power
Green LED
Off
Off
Off
Off
Off
On
On
Slow blink
Slow blink
Slow blink
Slow blink
Slow blink
6.
Observe the LEDs status for the Ethernet connection as described in the
following table.
The following table summarizes LED indicator combinations. Each Ethernet port has a
corresponding set of LEDs that provide a visual indication of the operating state.
Green LED
Blinks
Blinks
Blinks
26
StorageTek Dual 8Gb FC Dual GbE HBA, ExpressModule, Emulex Installation Guide For HBA Models SG-
XPCIEFCGBE-E8-Z, SG-PCIEFCGBE-E8-Z, SG-XPCIEFCGBE-E8-N, SG-PCIEFCGBE-E8-N and 7105393 • August
2018
Yellow LED
State
Off
Wake-up failure (failed board)
On
POST failure (failed board)
Slow blink
Wake-up failure monitor
Fast blink
Failure in POST
Flashing
POST processing in progress
Off
Failure while functioning
On
Failure while functioning
Off
Normal - link down
On
Not defined
Slow blink
Offline for download
Fast blink
Restricted offline mode (waiting for restart)
Flashing
Restricted offline mode, test active
Green/Yellow LED
State
Off
10-Mb link rate - Normal operating state, link up
Green
100-Mb link rate - Normal operating state, link up
Yellow
1-Gb link rate - Normal operating state, link up