8 ch, 24-bit, bridge and voltage input module, rack-mount terminal block (36 pages)
Summary of Contents for National Instruments REM-11154
Page 1
This document explains how to connect to the REM-11154. Note The guidelines in this document are specific to the REM-11154. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system.
Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Preparing the Environment Ensure that the environment in which you are using the REM-11154 meets the following specifications. Operating temperature -25 °C to 60 °C...
Verifying the Kit Contents Verify that the following items are included in the REM-11154 kit. Figure 1. REM-11154 Kit Contents 1. NI REM-11154 3. Supply voltage connector 2. Bus connector 4. Spring-terminal block (x4) Unpacking the Kit Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
White Bus coupler, power module Installing Bus Connectors What to Use • Bus connector • DIN rail What to Do Complete the following steps to install bus connectors on the DIN rail. 4 | ni.com | REM-11154 Getting Started Guide...
Note Verify that the bus connector socket aligns with the socket on the underside of the module. Press the REM-11154 directly onto the bus connector and DIN rail until it clicks into place. Caution Tilting the module when mounting it on the DIN rail will damage the contacts.
Page 8
Table 3. LED Indicators LED Color LED Pattern Indication Solid The REM-11154 is ready for operation. Green Flashing Data is invalid or unavailable. Green/ The REM-11154 cannot communicate Flashing Yellow with the connected devices. 8 | ni.com | REM-11154 Getting Started Guide...
Connection Guidelines • Make sure that devices you connect to the REM-11154 are compatible with the module specifications. • Push the wire into the terminal when using a solid wire or a stranded wire with a ferrule.
Removing Components Removing Spring Terminal Blocks Complete the following steps to remove a spring-terminal block from the REM-11154. Press the locking latch to release the spring-terminal block. Tilt the block toward the center of the module. Remove the connector from the module.
If you want to remove a bus connector in the middle of the system, you must remove any modules or bus connectors following the desired connector or slide them along the DIN rail at least 15.0 mm (0.60 in.). 12 | ni.com | REM-11154 Getting Started Guide...
Need help?
Do you have a question about the REM-11154 and is the answer not in the manual?
Questions and answers