Dell PowerVault 500 Owner's Manual page 10

Hide thumbs Also See for PowerVault 500:
Table of Contents

Advertisement

Invalid NVRAM configuration, Resource Re-
allocated
Keyboard Controller failure
Manufacturing mode detected
MEMBIST failure - The following DIMM/rank
has been disabled by BIOS: DIMM x Rank y
Memory address line failure at address,
read value expecting value
Memory double word logic failure at
address, read value expecting value
Memory odd/even logic failure at address,
read value expecting value
Memory write/read failure at address, read
value expecting value
Memory tests terminated by keystroke.
No boot device available
No boot sector on hard drive
No timer tick interrupt
Northbound merge error - The following
DIMM has been disabled by BIOS: DIMM x
Not a boot diskette
PCIe Degraded Link Width Error: Embedded
Bus#nn/Dev#nn/Funcn
Expected Link Width is n
Actual Link Width is n
PCIe Degraded Link Width Error: Slot n
Expected Link Width is n
Actual Link Width is n
PCIe Training Error: Embedded
Bus#nn/Dev#nn/Funcn
PCIe Training Error: Slot n
PCI BIOS failed to install
Plug & Play Configuration Error
Read fault
Requested sector not found
Remote configuration update attempt failed
ROM bad checksum = address
Sector not found
Seek error
Seek operation failed
Shutdown failure
The amount of system memory has changed
Time-of-day clock stopped
The following DIMM pair is not compatible
System detected and corrected a resource
conflict.
Faulty keyboard controller; faulty system board
System is in manufacturing mode.
Faulty memory module(s).
Faulty or improperly installed memory modules.
POST memory test terminated by pressing the
spacebar.
Faulty or missing optical/diskette drive
subsystem, hard drive, or hard-drive subsystem,
or no boot disk in drive A.
Incorrect configuration settings in System Setup
program, or no operating system on hard drive.
Faulty system board.
The specified DIMM was unable to establish a
successful data link with the memory controller.
No operating system on diskette.
Faulty or improperly installed PCIe card in the
specified slot.
Faulty or improperly installed PCIe card in the
specified slot.
Faulty or improperly installed PCIe card in the
specified slot.
PCI device BIOS (Option ROM) checksum failure
is detected during shadowing.
Loose cables to expansion card(s); faulty or
improperly installed expansion card(s).
Error encountered in initializing PCI device;
faulty system board.
The operating system cannot read from the
diskette or hard drive, the system could not find
a particular sector on the disk, or the requested
sector is defective.
System unable to process Remote Configuration
request
Expansion card improperly installed or faulty.
Faulty diskette or hard drive.
Shutdown test failure.
Memory has been added or removed or a
memory module may be faulty.
Faulty battery or faulty chip.
The specified DIMM(s) are incompatible with the
No action is required.
See
Getting
Help.
Reboot to take the system out of manufacturing mode.
See
Troubleshooting System
Memory.
See
Troubleshooting System
Memory.
Information only.
Use a bootable diskette, CD, or hard drive. If the problem
persists, see
Troubleshooting a Diskette
Troubleshooting an Optical
Drive, and
Hard
Drive. See
Using the System Setup Program
information on setting the order of boot devices.
Check the hard-drive configuration settings in the System
Setup program. See
Using the System Setup
necessary, install the operating system on your hard
drive. See your operating system documentation.
See
"Getting
Help."
See
Troubleshooting System
Memory.
Use a bootable diskette.
Reseat the PCIe card in the specified slot number. See
Expansion
Cards. If the problem persists, see
Help.
Reseat the PCIe card in the specified slot number. See
Expansion
Cards. If the problem persists, see
Help.
Reseat the PCIe card in the specified slot number. See
Expansion
Cards. If the problem persists, see
Help.
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see
Troubleshooting Expansion
Cards.
Install the NVRAM_CLR jumper and reboot the system.
See
Figure 6-1
for jumper location. If the problem
persists, see
Troubleshooting Expansion
Replace the diskette. Ensure that the diskette and hard
drive cables are properly connected. See
a USB
Device, or
Troubleshooting a Hard Drive
appropriate drive(s) installed in your system.
Retry Remote Configuration.
Reseat the expansion card(s). Ensure that all appropriate
cables are securely connected to the expansion card(s).
If the problem persists, see
Troubleshooting Expansion
Cards.
See
Troubleshooting a Diskette
Drive,
USB
Device, or
Troubleshooting a Hard Drive
appropriate drive(s) installed in your system.
See
Troubleshooting System
Memory.
If memory has been added or removed, this message is
informative and can be ignored. If memory has not been
added or removed, check the SEL to determine if single-
bit or multi-bit errors were detected and replace the
faulty memory module. See
Troubleshooting System
Memory.
See
Troubleshooting the System
Battery.
Ensure that only Dell-qualified memory is used. Dell
Drive,
Troubleshooting a
for
Program. If
Getting
Getting
Getting
Cards.
Troubleshooting
for the
Troubleshooting a
for the

Advertisement

Table of Contents
loading

Table of Contents