Safety Measures; Alarm Description - Casio FV-600BA Service Manual & Parts List

Table of Contents

Advertisement

The power will be turned off automatically when FV-600 is in the following conditions.
1. Fan is stopped.
2. High temperature
(1) Thermistor detects high temperature.
(2) Bimetal detects high temperature.
3. Fan filter is not set properly.
4. Rear cover is not set properly.
Power LED
Green On
OK
Off
Red On
Green Blink
Green On
NG
Red Blink
Red On

SAFETY MEASURES

ALARM DESCRIPTION

Alarm LED
Beep
Off
Off
Off
Off
Red Blink
Twice
Red Blink
Three times
Red Blink
Once
— 3 —
Description
Power on
Power off
Power off by remote control
Cooling off (Fan is working.)
High temperature warning
(Check the fan and fan filter.)
1. Lamp is defective.
2. Fan is defective.
1. Fan filter warning
(Check if the fun filter is set.)
2. Rear cover warning
(Check if the rear cover is set.)