Area light

Advertisement

Quick Links

FGP
Area Light
Installation Guide
Included components
Luminaire
Driver plate
assembly
Pole
Tools Required
• Safety glasses
• Wrenches, 1‐1/4" , 13mm
• Screwdrivers, Phillips and straight blade
• Wiring tools and connectors
• Proper personnel, crane or lift for hoisting unit onto anchors
• Level
• Dimming control, if required
• Hex keys, 8mm with 10‐12" extension, 5mm
• Twist lock photo eye control, if required
Landscape Forms is not responsible for site preparation and footings.  Refer to the 
installation guide for the FGP light anchor kit for installing the anchor bolts.
CAUTION! This unit is heavy. To avoid injury or damage to the finish, we recommend 
using a crane or lift for hoisting the unit onto the anchors.
WARNING! Pole mounted luminaires must be attached either before or immediately
after pole installation. Failure to do so may cause vibration damage to the pole and will 
void the pole warranty.
ASSEMBLE WITH CARE! Pangard II Polyester Powdercoat is a strong, long‐lasting finish.  To 
protect this finish during assembly, place unwrapped powdercoated parts on packaging foam or 
other non‐marring surface.  Do not place or slide powdercoated parts on concrete or other hard 
or textured surface – this will damage the finish causing rust to occur.  Use touch‐up paint on any 
gouges in the finish caused by assembly tools.
Twist lock receptacle,
2x ‐ Cover plate half
optional
Shorting cap for
Twist lock, optional
1x ‐ M10 x 1.5 x 55mm 
socket head cap screw 
with sealing washer
INSTALLATION PROCEDURE FOR LIGHT POLE:
1.
Lift the light pole into position over the installed anchors (refer to FGP area light 
anchor kit installation guide) as shown in Fig. 1.  Ensure that the base plate is resting 
on all four washers.
2.
Install washers and hexs nut as shown in Fig. 2.
3.
Plumb and level the pole and tighten all anchors.
4.
Connect line‐in wires to driver plate assembly. Pass wires through strain relief. See 
Fig. 3. Refer to wiring diagrams on page 3.
5.
Ensure that the wire harness connectors are pulled through the top of the driver 
plate assembly through the front cavity. This is to connect the luminaire wiring. 
6.
Gently insert the driver plate assembly into the top of the pole. Ensure the front of 
driver plate assembly is in the correct orientation. See Fig. 3 and 4.
7.
Apply downward pressure to compress the gasket. Tighten the six hex bolts equally 
using a 13mm wrench until snug. Ensure that once tightened, the driver plate 
assembly rests in the center of the pole.  
8.
Connect luminaire wiring to driver plate assembly, see Fig. 5.
9.
Gently push wires down inside of driver plate assembly. Set Luminaire on top of 
driver plate assembly, ensuring that the luminaire mount plate is seated properly on 
the top of the driver plate assembly. Use an 8mm hex key to install M10 x 55m socket 
head cap screw and sealing washer  to secure luminaire to top of pole.
10. If twist lock receptacle is specified, remove shorting cap and install photo‐eye control 
(not included), see Fig.6.
11. Install the cover plate as shown in Fig. 7 and 8. Use a 5mm hex key to tighten internal 
socket head cap screws to secure the two halves together.
INSTALLATION PROCEDURE FOR OPTIONAL PHOTO EYE:
Refer to wiring diagram for wiring details. 
1.
Remove the twist lock cap from the top of the light. 
2.
Loosen the two phillips head screws two turns.
IMPORTANT!  Do not remove the screws. Loosen just enough to rotate the receptacle.
3.
Rotate the receptacle until the arrow points north. Tighten the screws.
4.
Install the photo eye (not supplied with unit) rated for proper line voltage (277v, 
1.5A).
Date: October 5, 2018
www.landscapeforms.com
Ph: 800.521.2546
Page 1 of 3

Advertisement

loading

Summary of Contents for Landscape Forms FGP

  • Page 1 Area Light Date: October 5, 2018 Installation Guide www.landscapeforms.com Ph: 800.521.2546 Included components INSTALLATION PROCEDURE FOR LIGHT POLE: Lift the light pole into position over the installed anchors (refer to FGP area light  anchor kit installation guide) as shown in Fig. 1.  Ensure that the base plate is resting  on all four washers. Install washers and hexs nut as shown in Fig. 2. Twist lock receptacle, 2x ‐ Cover plate half optional Plumb and level the pole and tighten all anchors. Connect line‐in wires to driver plate assembly. Pass wires through strain relief. See  Luminaire Fig. 3. Refer to wiring diagrams on page 3. Ensure that the wire harness connectors are pulled through the top of the driver  Shorting cap for Driver plate plate assembly through the front cavity. This is to connect the luminaire wiring.  Twist lock, optional assembly 1x ‐ M10 x 1.5 x 55mm  Gently insert the driver plate assembly into the top of the pole. Ensure the front of  socket head cap screw  Pole driver plate assembly is in the correct orientation. See Fig. 3 and 4. with sealing washer Apply downward pressure to compress the gasket. Tighten the six hex bolts equally ...
  • Page 2 Area Light Date: October 5, 2018 Installation Guide www.landscapeforms.com Ph: 800.521.2546 HEX NUT 13mm WRENCH TO TIGHTEN FLAT  WASHER DRIVER PLATE LUMINAIRE TERMINAL  FRONT M10x1.5mm x  BLOCK 55mm SHCS SURGE SEALING  PROTECTOR WASHER Fig. 2 – Install pole Fig. 4 – Secure driver plate STRAIN RELIEF WIRING POLE HARNESS Fig. 5 ‐ Install luminaire Fig. 3 – Install driver plate Fig. 1 –...
  • Page 3 Area Light Date: October 5, 2018 Installation Guide www.landscapeforms.com Ph: 800.521.2546 PROCEDURE FOR WIRING FGP: The FGP luminaire is assembled at the factory.  The light cartridge is mounted into the head of the luminaire and will not need to be removed during installation.  The LED cartridge  needs to be connected to the driver plate assembly on site.  Use of LED drivers other than the supplied unit is not recommended and will void the warranty.  The wiring schematics are to be used to connect the unit to line voltage.  It is the responsibility of the installer to make sure that all connections are made in accordance with the NEC  and local building codes.  Connection hardware not included.  Line‐in wires should be connected to the terminal block as shown. Optional dimming control is not included. Note: Type 3 drivers do not include a ground wire. WIRING DIAGRAM:  No twist lock, With ground WIRING DIAGRAM:  With twist lock, with ground Page 3 of 3...