3. Once the thermostat is installed and properly configured,
test
the equipment by following these steps:
• Turn on power to the system.
• Fan Operation
• If your system does not have a "G" terminal
connection, skip to "Heating System" below.
• Press the "Fan" button on the thermostat and select the
"On" position. The blower should begin to operate.
• Press the "Mode" button to turn off the system. Then
press the "Fan" button on the thermostat and select the
"Auto" position. The blower should stop immediately.
• Circulating Fan
• Press the "Menu" button on the thermostat and press
the "Next" button until you reach the "Fn" screen.
• Adjust the % run time from 10%-100% in 5%
increments by using the arrow up or down
buttons (default is OFF), then press "Exit".
• The % run time is the percentage of time the
fan shall run in a day. This calculation takes into
account the amount of time the heating, cooling and
continuous fan have run during the same day.