Summary of Contents for Automated Logic UNI/59

  • Page 1: Table Of Contents

    Protection 10 Production Date 10 Automated Logic Corporation • 1150 Roberts Blvd. • Kennesaw, GA 30144 • 770/429-3000 • 770/429-3001 Fax • www.automatedlogic.com • Copyright 2001 Automated Logic Corporation. All rights reserved. Automated Logic, the Automated Logic logo, SuperVision, Eikon, Alert, and InterOp are registered trademarks of Automated Logic ®...
  • Page 2: Uni/59

    U-Line modules. You cannot use a & ' ( #)# combination of T-Line and U-Line modules % & with the UNI/59. The UNI/59 module can store one module driver and up to 59 Graphic   Function Blocks (GFBs), depending on the size of the GFBs.
  • Page 3: Mounting

    Status Indication Visual (LED) status of CMnet and Unet communication, Power Wiring running, errors, and power. CAUTION The UNI/59 module is a Class 2 Memory 1MB Flash memory and 1MB non- device (less than 30VAC, 100VA maximum). volatile battery-backed RAM.
  • Page 4: Communicating With The Uni/59

    Unet, as shown in Figure 3 modules on page 5. Make sure the Unet connection The UNI/59 supports up to 59 T-Line or U- port configuration jumpers are set to UNI and Line modules. If you are using T-Line EIA-485 (see Figure 4 on page 5).
  • Page 5: Connecting The Uni/59 To The Cmnet

    LEDs are active. When adding a new T-Line or U-Line module to an existing subnet, you must transfer memory to the UNI/59 before the new card is recognized. Connecting the UNI/59 to the CMnet Figure 6. Setting the CMnet port baud rate to 38.4 kbps or 9600 bps...
  • Page 6: Transferring Memory

    Make sure the FB List on this page shows Transferring Memory all the FBs you intended to transfer. The UNI/59 module can store the U5I or U5M module driver and up to 59 Graphic Function Using Flow Sensors Blocks (GFBs), depending on the size of the The UNI/59 supports T-Line or U-Line GFBs.
  • Page 7: Setting The Flow Sensor's Zero Point (T-Line Modules)

    2. Connect a DC95 or DC99 cable between attached correctly. the Diag Port and a computer that is • Make sure the UNI/59 and the T-Line or running a communications program like U-Line modules have power and are HyperTerminal or Terminal. To make your turned on.
  • Page 8: Communicating With The Workstation

    APT and the module’s Access port (see the UNI/59 module off first. Once you have Figure 10). This type of connection can be adjusted the switch, turn the module back on.
  • Page 9: Formatting The Module

    2. Set the APT’s Mode Select switch. LEDs The UNI/59 module has LED indicators to • On an ARC156 CMnet, use the TTL show the status of certain functions. Table 2 setting. explains the Run and Error LED signals in •...
  • Page 10: Protection

    Run LED Protection The UNI/59 module is protected by internal solid state Polyswitches on the incoming power and CMnet. These Polyswitches are not replaceable and will reset themselves if the condition that caused the fault returns to normal.